Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 2 pole NEMA Size 5 non-reversing contactor has a 270 ampere rating. Single phase NEMA Size 5 contactors have no horsepower ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 208 VAC 60 Hz coil that is wired for common control. This NEMA contactor is an open device without an enclosure. This contactor is 12.31 inches tall, 8.67 inches wide and 8.75 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
NEMA Contactor, Type S, nonreversing, Size 5, 270A, 1 phase, up to 100 kA, 2 pole, 208 VAC coil, open
NEMA Contactor, Type S, nonreversing, Size 5, 270A, 1 phase, up to 100 kA, 2 pole, 208 VAC coil, open
SKU: 16937012
Category: Starters & Contactors
Reviews (0)
Be the first to review “NEMA Contactor, Type S, nonreversing, Size 5, 270A, 1 phase, up to 100 kA, 2 pole, 208 VAC coil, open” Cancel reply
Related products
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
Non-Reversing Contactor, Size 2, 2-Pole, Open Style +Options
Non-Reversing Contactor, Size 2, 2-Pole, Open Style +Options
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 2 phase, 4 pole, melting alloy, 240 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 2 phase, 4 pole, melting alloy, 240 VAC coil, NEMA 1
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 60 A – 12 V DC standard coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 12 V DC standard coil
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 80 A – 12 V AC 50 Hz coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 80 A - 12 V AC 50 Hz coil
Contactor, Type L, multipole lighting, mechanically held, 30A, 3 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 3R/12
Contactor, Type L, multipole lighting, mechanically held, 30A, 3 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 3R/12
Reviews
There are no reviews yet.