This Multi9 N40N is a low voltage miniature circuit breaker (MCB). It is a 3P+N circuit breaker with 3 protected poles, 32A rated current and C tripping curve. The Icu rated short circuit breaking capacity is up to 10kA at 415VAC conforming to EN/IEC 60898-1 standard. This product complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. It has been designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. This product protects from short circuit, earth leakage and overload. Its fast closing mechanism, overvolatge resistance and high performance limitation improve its service life. This product is dedicated for original equipment manufacturers (OEM) and control panel builders. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 415VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The operating frequency is 50Hz or 60Hz. The product can be clipped on a DIN rail. Its width is 6 pitches of 9mm. Pollution degree is 3. The product colour is light grey (RAL7035). The dimensions are (W) 54mm x (H) 81mm x (D) 78mm. The weight is 0.322kg. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 70°C.
Miniature circuit breaker (MCB), Multi9 N40N, 3P+N, 32A, C curve, 10kA (IEC/EN 60947-2)
Miniature circuit breaker (MCB), Multi9 N40N, 3P+N, 32A, C curve, 10kA (IEC/EN 60947-2)
SKU: 4278142
Category: Power Distribution
Reviews (0)
Be the first to review “Miniature circuit breaker (MCB), Multi9 N40N, 3P+N, 32A, C curve, 10kA (IEC/EN 60947-2)” Cancel reply
Related products
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Multi 9 – C60 UL489 – MCB – 3P – 4 A – D Curve – 480Y/277 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 4 A - D Curve - 480Y/277 V - 10 kA - ring term
Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0A, 80%
Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0A, 80%
Mini CB, QO, 25 A, 2P, 120/240 V, 10 kA, Bolt on, PL
Mini CB, QO, 25 A, 2P, 120/240 V, 10 kA, Bolt on, PL
Circuit breaker, PowerPacT B, 70A, 2 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 70A, 2 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Reviews
There are no reviews yet.