This is a Multi GFP residual current circuit breaker (RCCB). It is a 2P circuit breaker with In rated current of 40A, A-SI type protection class and a 26mA earth leakage sensitivity. It protects persons against electric shock by direct contact. It also protects installations against fire risks. The tripping upon fault is indicated by a red mechanical status indicator on the front panel. The A-SI type offers enhanced immunity to electrical disturbances. This product is dedicated to original equipment manufacturers (OEM) and control panel builders in indisutrial and tertiary buildings. It is compliant with IEC/EN 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. It has a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product colour is light grey (RAL7035). The dimensions are (W) 36mm x (H) 81mm x (D) 60mm. The weight is 0.22kg. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -25°C to 60°C. The storage temperature is from -40°C to 70°C.
Residual current circuit breaker (RCCB), Multi9 GFP, 2P, 40A, A-SI type, 30mA
Residual current circuit breaker (RCCB), Multi9 GFP, 2P, 40A, A-SI type, 30mA
SKU: 3861937
Category: Power Distribution
Reviews (0)
Be the first to review “Residual current circuit breaker (RCCB), Multi9 GFP, 2P, 40A, A-SI type, 30mA” Cancel reply
Related products
Circuit breaker, PowerPacT B, 100A, 3 pole, 480Y/277VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 100A, 3 pole, 480Y/277VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT L, 250A, 3 pole, 600VAC, 50kA, lugs, MicroLogic 3.3S, 80%
Circuit breaker, PowerPacT L, 250A, 3 pole, 600VAC, 50kA, lugs, MicroLogic 3.3S, 80%
Mini CB, QO, 20 A, 2P, 120 V, 10 kA, Plug in, SWN, 50Deg
Mini CB, QO, 20 A, 2P, 120 V, 10 kA, Plug in, SWN, 50Deg
Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 14kA, lugs, thermal magnetic, 80%
Mini circuit breaker, QO, 15A, 1 pole, 120VAC, 10kA, plug in, dual function, pigtail
Mini circuit breaker, QO, 15A, 1 pole, 120VAC, 10kA, plug in, dual function, pigtail
Multi 9 – C60 UL489 – MCB – 3P – 13 A – D Curve – 240 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 13 A - D Curve - 240 V - 10 kA - ring term
EZ Meter Main Busway Tap Right Side, Neutral Back, Mn Brkr, 1200A, 3PH, 65 kA
EZ Meter Main Busway Tap Right Side, Neutral Back, Mn Brkr, 1200A, 3PH, 65 kA
Reviews