PowerPacT H-Frame motor circuit protectors (MCP) are instantaneous-trip circuit breakers designed to offer short circuit protection for motors. The unique design of the PowerPacT MCPs accommodates transient motor inrush current without nuisance tripping. This PowerPacT H, 150A, 3 pole, motor protector has a breaking capacity of 100kA at 600VAC. This unit has lugs on both the line and load side. These motor protectors accept the same accessories and terminals as PowerPacT H circuit breakers. This breaker has a continuous current rating of 80%. PowerPacT H motor circuit protectors comply to UL, CSA, and IEC standards and are CE marked.
Motor circuit protector, PowerPacT H, 150A, 3 pole, 600VAC, 100kA, lugs, thermal magnetic, 80%
Motor circuit protector, PowerPacT H, 150A, 3 pole, 600VAC, 100kA, lugs, thermal magnetic, 80%
SKU: 172551527
Category: Circuit Breakers
Reviews (0)
Be the first to review “Motor circuit protector, PowerPacT H, 150A, 3 pole, 600VAC, 100kA, lugs, thermal magnetic, 80%” Cancel reply
Related products
Circuit breaker, PowerPacT H, 50A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 100%
Circuit breaker, PowerPacT H, 50A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 100%
Circuit breaker, PowerPacT B, 30A, 3 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 30A, 3 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPact L, unit mount, Micrologic 3.3S, 600A, 3 pole, 35kA, 480VAC, 80% rated, mission critical
Circuit breaker, PowerPact L, unit mount, Micrologic 3.3S, 600A, 3 pole, 35kA, 480VAC, 80% rated, mission critical
Circuit breaker, PowerPacT B, 60A, 1 pole, 600Y/347VAC, 25kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 60A, 1 pole, 600Y/347VAC, 25kA, lugs, thermal magnetic, 80%
Miniature circuit breaker (MCB), Multi9 C60BP, 1P, 5A, D curve, 14kA (UL489), 10kA (IEC/EN 60947-2)
Miniature circuit breaker (MCB), Multi9 C60BP, 1P, 5A, D curve, 14kA (UL489), 10kA (IEC/EN 60947-2)
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker, PowerPacT H, 100A, 3 pole, 600VAC, 50kA, I-Line, Micrologic 5.2E, 80%, ABC
Circuit breaker, PowerPacT H, 100A, 3 pole, 600VAC, 50kA, I-Line, Micrologic 5.2E, 80%, ABC
Circuit breaker, PowerPacT P, I-Line, Micrologic 5.0, 400A, 3 pole, 25kA, 600VAC, phase ABC, shunt trip, 80% rated
Circuit breaker, PowerPacT P, I-Line, Micrologic 5.0, 400A, 3 pole, 25kA, 600VAC, phase ABC, shunt trip, 80% rated