QO and QOB one, two and three pole thermal magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. These circuit breakers have an over center, trip free toggle mechanism with quick make, quick break action and positive handle indication. They also have VisiTrip trip indication, which provides a visual indication that the circuit breaker has tripped and interrupted the circuit. A full line of features and factory installed accessories are also available such as shunt trips, auxiliary switches and alarm switches. This 1 pole QO circuit breaker is rated at 20A at 120VAC. This unit provides 22kA breaking capacity and bolt on mounting. This product includes a 6mA ground fault A with pigtail. QO circuit breakers are UL Listed under UL File E84967 and are CSA Certified under CSA Master Contract 153555.
Mini circuit breaker, QO, 20A, 1 pole, 120VAC, 22kA, bolt on, 6mA grd fault A, pigtail
Mini circuit breaker, QO, 20A, 1 pole, 120VAC, 22kA, bolt on, 6mA grd fault A, pigtail
SKU: 15217824
Category: Power Distribution
Reviews (0)
Be the first to review “Mini circuit breaker, QO, 20A, 1 pole, 120VAC, 22kA, bolt on, 6mA grd fault A, pigtail” Cancel reply
Related products
Mini circuit breaker, QO, 15A, 1 pole, 120VAC, 10kA, plug in, dual function, pigtail
Mini circuit breaker, QO, 15A, 1 pole, 120VAC, 10kA, plug in, dual function, pigtail
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 14kA, lugs, thermal magnetic, 80%
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Circuit breaker, PowerPacT H, 80A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt, control wire both
Circuit breaker, PowerPacT H, 80A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt, control wire both
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0A, 80%
Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0A, 80%
Multi 9 – C60 UL489 – MCB – 3P – 4 A – D Curve – 480Y/277 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 4 A - D Curve - 480Y/277 V - 10 kA - ring term
Reviews
There are no reviews yet.