Square D EZ Meter-Pak main devices are available as main circuit breakers, main fusible switches, or main lug terminal boxes. EZM main fusible switch with busway side tap have an integral busway tap allowing for connection to I-Line or I-Line II plug in busway. This main circuit breaker unit supplies three phases in, three phases out with a four wire configuration. This unit has busway taps extending to the right of the main device and allows neutral front installation. It is rated for 208Y/120VAC or 240/120VAC delta and 1200A. The compartment accepts Class T 300VAC fuses (order separately). The compartment has four horizontal 1200A rated busbars. The busbars come with Visi-Tite joint nuts for connections, eliminating the need for torque readings. It is compliant with UL standards and the steel enclosure has a rating of NEMA 1.
Main fusible switch unit, EZ Meter-Pak, bus side tap, 1200A, 3 phase, 4 wire, 1200A bus, T fuses, neut front, tap right
Main fusible switch unit, EZ Meter-Pak, bus side tap, 1200A, 3 phase, 4 wire, 1200A bus, T fuses, neut front, tap right
SKU: 172546855
Category: Meters & Accessories
Reviews (0)
Be the first to review “Main fusible switch unit, EZ Meter-Pak, bus side tap, 1200A, 3 phase, 4 wire, 1200A bus, T fuses, neut front, tap right” Cancel reply
Related products
PowerLogic ION9000 Current Input hardware kit – terminal screws, CT covers
PowerLogic ION9000 Current Input hardware kit – terminal screws, CT covers
PowerLogic EM3500 DIN rail meter – BACnet – flexible transducer
PowerLogic EM3500 DIN rail meter - BACnet - flexible transducer
Branch unit, EZ Meter-Pak, 225A, 3 x 5 jaw sockets, 120/240VAC, no bypass, ringless, 800A Al busbar
Branch unit, EZ Meter-Pak, 225A, 3 x 5 jaw sockets, 120/240VAC, no bypass, ringless, 800A Al busbar
Branch unit, EZ Meter-Pak, 225A, 4 sockets, 120/240 VAC, no bypass, ringed, 1200A Cu busbar
Branch unit, EZ Meter-Pak, 225A, 4 sockets, 120/240 VAC, no bypass, ringed, 1200A Cu busbar
Meter mains, Homeline, CSED, ringed socket, 200A, outdoor semi flush mount, maximum 8 spaces, 16 circuits, no bypass
Meter mains, Homeline, CSED, ringed socket, 200A, outdoor semi flush mount, maximum 8 spaces, 16 circuits, no bypass
Main circuit breaker unit, EZ Meter-Pak, 2000A, 120/240VAC, 1ph/3W, 1200A bus, 65kA, UG, Type 3R
Main circuit breaker unit, EZ Meter-Pak, 2000A, 120/240VAC, 1ph/3W, 1200A bus, 65kA, UG, Type 3R
ION7550 – wDispl – 5MB 256s – 5A 60VDC 60Hz – RS+T2+E – 8I+3R+4O
ION7550 - wDispl - 5MB 256s - 5A 60VDC 60Hz - RS+T2+E - 8I+3R+4O
Branch unit, EZ Meter-Pak, 225A, 5 x 5 jaw sockets, 208Y/120VAC, horn bypass, ringless, 1200A Cu busbar
Branch unit, EZ Meter-Pak, 225A, 5 x 5 jaw sockets, 208Y/120VAC, horn bypass, ringless, 1200A Cu busbar
Reviews
There are no reviews yet.