QO load centers offer premium features by allowing QO breakers, ground arc fault interrupters arc fault interrupters and surge arresters to be installed inside QO load centers enable the use of a full complement of accessories. Systems can be single or three phase and have indoor and outdoor versions. Indoor enclosures are designed to rotate 180 degrees to accommodate top or bottom service entrance feed which saves expensive service cable. QO load centers feature plated copper bus, providing superior performance and durability. This single phase QO load center has fixed mains and is rated at 100 A at 120/240 VAC. This QO load center has a 10 kA breaking capacity. This system provides 8 spaces in a NEMA 1 enclosure. This load center has a surface cover. The lugs will accept 8 AWG to 1 AWG copper or aluminum wire. The load center is 12.56 inches tall, 8.90 inches wide and 3.74 inches deep. The load center is CSA certified.
Load center, QO, 1 phase, 8 spaces, 8 circuits, 100A convertible main lugs, NEMA1, surface cover, UL
Load center, QO, 1 phase, 8 spaces, 8 circuits, 100A convertible main lugs, NEMA1, surface cover, UL
SKU: 172560082
Category: Load Centers & Panel Boards
Reviews (0)
Be the first to review “Load center, QO, 1 phase, 8 spaces, 8 circuits, 100A convertible main lugs, NEMA1, surface cover, UL” Cancel reply
Related products
Panelboard enclosure cover, NQ, NEMA 1, flush, 15.52in W x 39.52in H
Panelboard enclosure cover, NQ, NEMA 1, flush, 15.52in W x 39.52in H
Interior, I-Line Panelboard, HCP, 800A, w/main breaker, 72in CB space, for 42in W x 86in H x 9.5in D box, Cu bus
Interior, I-Line Panelboard, HCP, 800A, w/main breaker, 72in CB space, for 42in W x 86in H x 9.5in D box, Cu bus
Panelboard accessory, NF, deadfront branch kit, 400A, 1 phase, 54 circuits
Panelboard accessory, NF, deadfront branch kit, 400A, 1 phase, 54 circuits
Trim, I-Line PNLBRD, hcp, flush, 4 pcs, w/door, 42×50 in
Trim, I-Line PNLBRD, hcp, flush, 4 pcs, w/door, 42x50 in
Mini circuit breaker, E-Frame, 60A, 3 pole, 480Y/277 VAC, 100 kA max, bolt on, shunt trip
Mini circuit breaker, E-Frame, 60A, 3 pole, 480Y/277 VAC, 100 kA max, bolt on, shunt trip
Interior, I-Line PNLBRD, 400 A, main lugs, 31.50 in bar
Interior, I-Line PNLBRD, 400 A, main lugs, 31.50 in bar
NQ Panelboard Acc. Mechanical Lug Kit 225A, Aluminum/Copper
NQ Panelboard Acc. Mechanical Lug Kit 225A, Aluminum/Copper
Mini circuit breaker accessory, QO, clamp, handle, for holding in ON or OFF position
Mini circuit breaker accessory, QO, clamp, handle, for holding in ON or OFF position
Reviews
There are no reviews yet.