QO load centers offer premium features by allowing QO breakers, ground arc fault interrupters arc fault interrupters and surge arresters to be installed inside QO load centers enable the use of a full complement of accessories. Systems can be single or three phase and have indoor and outdoor versions. Indoor enclosures are designed to rotate 180 degrees to accommodate top or bottom service entrance feed which saves expensive service cable. QO load centers feature plated copper bus, providing superior performance and durability. This single phase QO load center has fixed mains and is rated at 100 A at 120/240 VAC. This QO load center has a 10 kA breaking capacity. This system provides 6 spaces in a NEMA 1 enclosure. This load center has a surface cover. The lugs will accept 8 AWG to 1 AWG copper or aluminum wire. The load center is 12.56 inches tall, 8.90 inches wide and 3.74 inches deep. The load center is CSA certified.
Load center, QO, 1 phase, 6 spaces, 6 circuits, 100A convertible main lugs, NEMA1, surface cover, UL
Load center, QO, 1 phase, 6 spaces, 6 circuits, 100A convertible main lugs, NEMA1, surface cover, UL
SKU: 172561181
Category: Load Centers & Panel Boards
Reviews (0)
Be the first to review “Load center, QO, 1 phase, 6 spaces, 6 circuits, 100A convertible main lugs, NEMA1, surface cover, UL” Cancel reply
Related products
Panelboard enclosure box, NQ, Type 1, 14in W x 44in H x 5.75in D
Panelboard enclosure box, NQ, Type 1, 14in W x 44in H x 5.75in D
Mini circuit breaker accessory, QO, clamp, handle, for holding in ON or OFF position
Mini circuit breaker accessory, QO, clamp, handle, for holding in ON or OFF position
Mini circuit breaker, E-Frame, 20A, 3 pole, 480Y/277 VAC, 25 kA max, bolt on, aux switch, alarm switch
Mini circuit breaker, E-Frame, 20A, 3 pole, 480Y/277 VAC, 25 kA max, bolt on, aux switch, alarm switch
Trim, I-Line PNLBRD, hcp, flush, 4 pcs, w/door, 42×50 in
Trim, I-Line PNLBRD, hcp, flush, 4 pcs, w/door, 42x50 in
Interior, I-Line PNLBRD, 400 A, main lugs, 31.50 in bar
Interior, I-Line PNLBRD, 400 A, main lugs, 31.50 in bar
OEM Mounting Base, ASE, 16 SP 125A, W/Lugs, No Neutral
OEM Mounting Base, ASE, 16 SP 125A, W/Lugs, No Neutral
Load center, QO, 3 phase, 42 spaces, 42 circuits, 125A convertible main breaker, NEMA3R, QDL, UL
Load center, QO, 3 phase, 42 spaces, 42 circuits, 125A convertible main breaker, NEMA3R, QDL, UL
Interior, I-Line Panelboard, HCP, 800A, w/main breaker, 72in CB space, for 42in W x 86in H x 9.5in D box, Cu bus
Interior, I-Line Panelboard, HCP, 800A, w/main breaker, 72in CB space, for 42in W x 86in H x 9.5in D box, Cu bus

Reviews
There are no reviews yet.