QO load centers offer premium features by allowing QO breakers, ground arc fault interrupters arc fault interrupters and surge arresters to be installed inside QO load centers enable the use of a full complement of accessories. Systems can be single or three phase and have indoor and outdoor versions. Indoor enclosures are designed to rotate 180 degrees to accommodate top or bottom service entrance feed which saves expensive service cable. QO load centers feature plated copper bus, providing superior performance and durability. This single phase QO load center has fixed mains and is rated at 100 A at 120/240 VAC. This QO load center has a 10 kA breaking capacity. This system provides 4 spaces in a NEMA 1 enclosure. This load center has a surface cover. The lugs will accept 8 AWG to 1 AWG copper or aluminum wire. The load center is 12.56 inches tall, 8.90 inches wide and 3.74 inches deep. The load center is CSA certified.
Load center, QO, 1 phase, 4 spaces, 4 circuits, 100A convertible main lugs, NEMA1, surface cover, CSA
Load center, QO, 1 phase, 4 spaces, 4 circuits, 100A convertible main lugs, NEMA1, surface cover, CSA
SKU: 172567380
Category: Load Centers & Panel Boards
Reviews (0)
Be the first to review “Load center, QO, 1 phase, 4 spaces, 4 circuits, 100A convertible main lugs, NEMA1, surface cover, CSA” Cancel reply
Related products
Load center, QO, 3 phase, 42 spaces, 42 circuits, 125A convertible main breaker, NEMA3R, QDL, UL
Load center, QO, 3 phase, 42 spaces, 42 circuits, 125A convertible main breaker, NEMA3R, QDL, UL
Trim, I-Line PNLBRD, hcp, flush, 4 pcs, w/door, 42×50 in
Trim, I-Line PNLBRD, hcp, flush, 4 pcs, w/door, 42x50 in
Interior, I-Line Panelboard, HCP, 800A, w/main breaker, 72in CB space, for 42in W x 86in H x 9.5in D box, Cu bus
Interior, I-Line Panelboard, HCP, 800A, w/main breaker, 72in CB space, for 42in W x 86in H x 9.5in D box, Cu bus
NF Panelboard Acc. Branch Deadfront Kit 125A, 3 Phase, 54 CCT, Thru Feed Lug
NF Panelboard Acc. Branch Deadfront Kit 125A, 3 Phase, 54 CCT, Thru Feed Lug
OEM Mounting Base, ASE, 16 SP 125A, W/Lugs, No Neutral
OEM Mounting Base, ASE, 16 SP 125A, W/Lugs, No Neutral
Load center accessory, QO, mounting base, 1 phase, 6 spaces, OEM, copper neutral, special
Load center accessory, QO, mounting base, 1 phase, 6 spaces, OEM, copper neutral, special
Load center, QO, 1 phase, 30 spaces, 30 circuits, 200A convertible main breaker, PoN, NEMA1, Qwik-grip, UL
Load center, QO, 1 phase, 30 spaces, 30 circuits, 200A convertible main breaker, PoN, NEMA1, Qwik-grip, UL
Panelboard interior, NQ, main breaker, 225A, Cu bus, 42 pole spaces, 3 phase, 4 wire, 240VAC, 48VDC, column width
Panelboard interior, NQ, main breaker, 225A, Cu bus, 42 pole spaces, 3 phase, 4 wire, 240VAC, 48VDC, column width

Reviews
There are no reviews yet.