The Homeline load center offer features Homeline circuit breakers, ground fault circuit breakers and arc fault interrupters. Homeline load centers enable the use of a full complement of accessories. Systems are single phase and are rated for indoor use or are rain proof. Homeline load centers are designed for residential and industrial use to protect electrical systems, equipment and people. This Homeline load center is supplied with convertible mains that are rated at 125A 120/240 VAC single phase. Homeline load center provides a 10 kA breaking capacity. This system provides 30 spaces in a NEMA 1 indoor enclosure with a combination flush/surface indoor cover. The electrical connections are box lugs. The box lugs will accept a wire range of 6 AWG to 2/0 AWG copper or aluminum wire. Load center has a grounding bar. The Homeline load center comes with a Qwik grip assembly kit. This Homeline load center has a height of 33.77 inches, a width of 14.25 inches, and depth of 3.74 inches. Homeline load centers are UL Listed.
Load center, Homeline, 1 phase, 30 spaces, 60 circuits, 125A convertible main lugs, PoN, NEMA1, Qwik-grip, gnd bar
Load center, Homeline, 1 phase, 30 spaces, 60 circuits, 125A convertible main lugs, PoN, NEMA1, Qwik-grip, gnd bar
SKU: 172551227
Category: Load Centers & Panel Boards
Reviews (0)
Be the first to review “Load center, Homeline, 1 phase, 30 spaces, 60 circuits, 125A convertible main lugs, PoN, NEMA1, Qwik-grip, gnd bar” Cancel reply
Related products
Panelboard accessory, NF, number strip, odd/even, 103 to 204
Panelboard accessory, NF, number strip, odd/even, 103 to 204
Interior, I-Line Panelboard, HCP, 800A, w/main breaker, 72in CB space, for 42in W x 86in H x 9.5in D box, Cu bus
Interior, I-Line Panelboard, HCP, 800A, w/main breaker, 72in CB space, for 42in W x 86in H x 9.5in D box, Cu bus
Interior, I-Line PNLBRD, hcm, 800 A, main lugs, 32x48x8.25 in
Interior, I-Line PNLBRD, hcm, 800 A, main lugs, 32x48x8.25 in
Load center, QO, 3 phase, 42 spaces, 42 circuits, 125A convertible main breaker, NEMA3R, QDL, UL
Load center, QO, 3 phase, 42 spaces, 42 circuits, 125A convertible main breaker, NEMA3R, QDL, UL
Mini circuit breaker, E-Frame, 60A, 3 pole, 480Y/277 VAC, 100 kA max, bolt on, shunt trip
Mini circuit breaker, E-Frame, 60A, 3 pole, 480Y/277 VAC, 100 kA max, bolt on, shunt trip
Panelboard interior, NQ, main breaker, 225A, Cu bus, 42 pole spaces, 3 phase, 4 wire, 240VAC, 48VDC, column width
Panelboard interior, NQ, main breaker, 225A, Cu bus, 42 pole spaces, 3 phase, 4 wire, 240VAC, 48VDC, column width
Panelboard accessory, NQ, lug kit, compression, 100A, 8 to 1/0 AWG, Al
Panelboard accessory, NQ, lug kit, compression, 100A, 8 to 1/0 AWG, Al
Reviews
There are no reviews yet.