Individual Meter Sockets are available for single or three phase with a 600 VAC maximum. These individual meter sockets can be with and without horn or lever bypass. The sockets have a 10 kA short circuit current rating as standard but could have a higher rating with utility approval. Units are supplied with a bonded neutral. Units are supplied with a hub opening in top end wall which requires the use of a bolt on hub or a closing plate. This ringless meter socket has four jaws with no bypass and without jaw release. This meter socket is for single phase 3 wire systems up to 600 VAC. This meter socket has a 200 A rating. This unit can be for a feed from an overhead or underground service. This unit has a NEMA 3R surface mounting enclosure that is 15.00 inches tall, 11.00 inches wide and 4.38 inches deep. The main lugs, the load lugs and the neutral lug will accept one 1/0 AWG to 350 kcmil copper or aluminum wire. The ground will accept 14 AWG to 2 AWG copper or aluminum wire. This individual meter socket is UL Listed.
Individual meter socket, ringless socket, no bypass, 4 jaws no release, OH, UG, 200 A, up to 600 VAC single phase 3W
Individual meter socket, ringless socket, no bypass, 4 jaws no release, OH, UG, 200 A, up to 600 VAC single phase 3W
SKU: 172556749
Category: Meters & Accessories
Reviews (0)
Be the first to review “Individual meter socket, ringless socket, no bypass, 4 jaws no release, OH, UG, 200 A, up to 600 VAC single phase 3W” Cancel reply
Related products
Branch unit, EZ Meter-Pak, 125A, 4 sockets, 208Y/120VAC, horn bypass, ringless, 1200A Cu busbar
Branch unit, EZ Meter-Pak, 125A, 4 sockets, 208Y/120VAC, horn bypass, ringless, 1200A Cu busbar
Main circuit breaker unit, EZ Meter-Pak, 1200A, 120/240VAC, 1ph/3W, 1200A bus, 100kA, UG, Type 3R, ERMS
Main circuit breaker unit, EZ Meter-Pak, 1200A, 120/240VAC, 1ph/3W, 1200A bus, 100kA, UG, Type 3R, ERMS
Meter mains, QO, CSED, ringless socket, 200A, surface mount, horn bypass
Meter mains, QO, CSED, ringless socket, 200A, surface mount, horn bypass
Branch unit, EZ Meter-Pak, 225A, 4 sockets, 120/240 VAC, no bypass, ringed, 1200A Cu busbar
Branch unit, EZ Meter-Pak, 225A, 4 sockets, 120/240 VAC, no bypass, ringed, 1200A Cu busbar
Main circuit breaker unit, EZ Meter-Pak, 2000A, 120/240VAC, 1ph/3W, 1200A bus, 65kA, UG, Type 3R
Main circuit breaker unit, EZ Meter-Pak, 2000A, 120/240VAC, 1ph/3W, 1200A bus, 65kA, UG, Type 3R
ION8650 meter 128MB, FT21 panel, 277VAC 60Hz, Ethernet No I/O
ION8650 meter 128MB, FT21 panel, 277VAC 60Hz, Ethernet No I/O
Meter mains, QO, CSED, ringed socket, 200A, surface mount, no bypass
Meter mains, QO, CSED, ringed socket, 200A, surface mount, no bypass
Reviews
There are no reviews yet.