Individual Meter Sockets are available for single or three phase with a 600 VAC maximum. These individual meter sockets can be with and without horn or lever bypass. The sockets have a 10 kA short circuit current rating as standard but could have a higher rating with utility approval. Units are supplied with a bonded neutral. Units are supplied with a hub opening in top end wall which requires the use of a bolt on hub or a closing plate. This ringless meter socket has four jaws with no bypass and without jaw release. This meter socket is for single phase 3 wire systems up to 600 VAC. This meter socket has a 125 A rating. This unit can be for a feed from an overhead or underground service. This unit has a NEMA 3R surface mounting enclosure that is 10.88 inches tall, 8.00 inches wide and 3.50 inches deep. The main lugs, the load lugs and the neutral lug will accept one 8 AWG to 2/0 AWG copper or aluminum wire. The ground will accept 14 AWG to 2 AWG copper or aluminum wire. This individual meter socket is UL Listed.
Individual meter socket, ringless socket, no bypass, 4 jaws no release, OH, UG, 125 A, up to 600 VAC single phase 3W
Individual meter socket, ringless socket, no bypass, 4 jaws no release, OH, UG, 125 A, up to 600 VAC single phase 3W
SKU: 15443660
Category: Meters & Accessories
Reviews (0)
Be the first to review “Individual meter socket, ringless socket, no bypass, 4 jaws no release, OH, UG, 125 A, up to 600 VAC single phase 3W” Cancel reply
Related products
PowerLogic EM3500 DIN rail meter – BACnet – flexible transducer
PowerLogic EM3500 DIN rail meter - BACnet - flexible transducer
PowerLogic ION9000 Current Input hardware kit – terminal screws, CT covers
PowerLogic ION9000 Current Input hardware kit – terminal screws, CT covers
Meter mains, QO, CSED, ringless socket, 150A, surface mount, maximum 8 spaces, 16 circuits, no bypass
Meter mains, QO, CSED, ringless socket, 150A, surface mount, maximum 8 spaces, 16 circuits, no bypass
Main circuit breaker unit, EZ Meter-Pak, 2000A, 120/240VAC, 1ph/3W, 1200A bus, 65kA, UG, Type 3R
Main circuit breaker unit, EZ Meter-Pak, 2000A, 120/240VAC, 1ph/3W, 1200A bus, 65kA, UG, Type 3R
Branch unit, EZ Meter-Pak, 225A, 3 x 5 jaw sockets, 120/240VAC, no bypass, ringless, 800A Al busbar
Branch unit, EZ Meter-Pak, 225A, 3 x 5 jaw sockets, 120/240VAC, no bypass, ringless, 800A Al busbar
Branch unit, EZ Meter-Pak, 225A, 4 sockets, 120/240 VAC, no bypass, ringed, 1200A Cu busbar
Branch unit, EZ Meter-Pak, 225A, 4 sockets, 120/240 VAC, no bypass, ringed, 1200A Cu busbar
EZ Meter Pak, transition section, right, 1200 A bus, 120/240 VAC single phase
EZ Meter Pak, transition section, right, 1200 A bus, 120/240 VAC single phase
Switchgear accessory, Masterclad, bus boot, 1.2kA/3kA
Switchgear accessory, Masterclad, bus boot, 1.2kA/3kA