Individual Meter Sockets are available for single or three phase with a 600 VAC maximum. These individual meter sockets can be with and without horn or lever bypass. The sockets have a 10 kA short circuit current rating as standard but could have a higher rating with utility approval. Units are supplied with a bonded neutral. Units are supplied with a hub opening in top end wall which requires the use of a bolt on hub or a closing plate. This ringless meter socket has seven jaws with lever bypass and jaw release. This meter socket is for three phase 3 wire systems up to 600 VAC. This meter socket has a 320 A rating. This unit must be fed from an overhead service. This unit has a NEMA 3R surface mounting enclosure. The main lugs, the load lugs and the neutral lug will accept one 4 AWG to 600 kcmil copper or aluminum wire. The ground will accept 6 AWG to 350 kcmil copper or aluminum wire. This individual meter socket is UL Listed.
Individual meter socket, ringless socket, lever bypass, 7 jaws no release, OH, 320 A, up to 600 VAC three phase 4W
Individual meter socket, ringless socket, lever bypass, 7 jaws no release, OH, 320 A, up to 600 VAC three phase 4W
SKU: 9002092
Category: Power Distribution
Reviews (0)
Be the first to review “Individual meter socket, ringless socket, lever bypass, 7 jaws no release, OH, 320 A, up to 600 VAC three phase 4W” Cancel reply
Related products
Multi 9 – C60 UL489 – MCB – 3P – 4 A – D Curve – 480Y/277 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 4 A - D Curve - 480Y/277 V - 10 kA - ring term
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Circuit breaker, PowerPacT H, 110A, 2 pole, 600VAC, 14kA, I-Line, thermal magnetic, 80%, CB
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Circuit breaker, PowerPacT H, 80A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt, control wire both
Circuit breaker, PowerPacT H, 80A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt, control wire both
Mini CB, QO, 25 A, 2P, 120/240 V, 10 kA, Bolt on, PL
Mini CB, QO, 25 A, 2P, 120/240 V, 10 kA, Bolt on, PL

Reviews
There are no reviews yet.