horizontal ganged meter sockets are for single phase systems up to 600 VAC. These meter socket units can be from 2 through 6 meter positions. Units can be with or with a horn or lever bypass and be fed from the end or the center. This horizontal ganged meter socket has three meter positions without bypass. Each socket position has a 4 jaw socket without jaw release. The main is rated at 100 A. This unit can be feed from an overhead or underground service. This unit has a NEMA 3R surface mounting enclosure that is 14.12 inches tall, 32.50 inches wide and 4.50 inches deep. The main lugs will accept 6 AWG to 250 kcmil copper or aluminum wire. The branch lugs will accept 8 AWG to 2/0 AWG copper or aluminum wire. This horizontal ganged meter socket device is UL Listed.
Horizontal meter sockets, 3 ringed sockets, no bypass, 4 jaws, OH, UG, 100 A
Horizontal meter sockets, 3 ringed sockets, no bypass, 4 jaws, OH, UG, 100 A
SKU: 8964309
Category: Power Distribution
Reviews (0)
Be the first to review “Horizontal meter sockets, 3 ringed sockets, no bypass, 4 jaws, OH, UG, 100 A” Cancel reply
Related products
Circuit breaker, PowerPacT H, 80A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt, control wire both
Circuit breaker, PowerPacT H, 80A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 80%, shunt, control wire both
Miniature circuit breaker (MCB), Multi9 C60H, 2P, 16A, C curve, 15kA (IEC/EN 60947-2)
Miniature circuit breaker (MCB), Multi9 C60H, 2P, 16A, C curve, 15kA (IEC/EN 60947-2)
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 40A, 2 pole, 600Y/347VAC, 25kA, terminal nut, thermal magnetic, 80%
Multi 9 – C60 UL489 – MCB – 3P – 4 A – D Curve – 480Y/277 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 4 A - D Curve - 480Y/277 V - 10 kA - ring term
Circuit breaker, PowerPacT B, 70A, 2 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 70A, 2 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT L, 250A, 3 pole, 600VAC, 50kA, lugs, MicroLogic 3.3S, 80%
Circuit breaker, PowerPacT L, 250A, 3 pole, 600VAC, 50kA, lugs, MicroLogic 3.3S, 80%
Automatic switch, PowerPacT J, 225A, 3 pole, 600VAC, 18kA, lugs, magnetic
Automatic switch, PowerPacT J, 225A, 3 pole, 600VAC, 18kA, lugs, magnetic
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Reviews
There are no reviews yet.