QO generator panels are for the manual transfer from utility to generator power. QO generator panels are for back-up power applications. This sub-panel connects directly to the main load center and provides four single pole spaces that will accommodate up to eight circuits dedicated for back-up power. This QO generator panel uses two factory installed, two pole QO circuit breakers. One is fed by the utility, while the second circuit breaker is back-fed to the back-up power source, such as a generator. Power source switching is easy. Simply turn the main power breaker to the “OFF” position and then turn the generator fed breaker to the “ON” position. A factory installed mechanical interlock prevents both main breakers being in the “ON” position at the same time. This NEMA 1 enclosure with a surface cover with a door is for indoor applications. This panel has a 30A rating and a 10 kA short circuit current rating. The lugs will accept 14 AWG to 8 AWG copper or aluminum wire. This QO generator panel has a height of 12.57 inches, a width of 8.88 inches and a depth of 3.80 inches. This generator panel is UL Listed.
Generator panel, QO, 1 phase, 4 spaces, 8 circuits, 30A main breaker with interlock, NEMA1, surface cover door, UL
Generator panel, QO, 1 phase, 4 spaces, 8 circuits, 30A main breaker with interlock, NEMA1, surface cover door, UL
SKU: 172546737
Category: Load Centers & Panel Boards
Reviews (0)
Be the first to review “Generator panel, QO, 1 phase, 4 spaces, 8 circuits, 30A main breaker with interlock, NEMA1, surface cover door, UL” Cancel reply
Related products
Interior, I-Line Panelboard, HCP, 800A, w/main breaker, 72in CB space, for 42in W x 86in H x 9.5in D box, Cu bus
Interior, I-Line Panelboard, HCP, 800A, w/main breaker, 72in CB space, for 42in W x 86in H x 9.5in D box, Cu bus
Panelboard accessory, NQ, lug kit, compression, 100A, 8 to 1/0 AWG, Al
Panelboard accessory, NQ, lug kit, compression, 100A, 8 to 1/0 AWG, Al
Load center, QO, 3 phase, 42 spaces, 42 circuits, 125A convertible main breaker, NEMA3R, QDL, UL
Load center, QO, 3 phase, 42 spaces, 42 circuits, 125A convertible main breaker, NEMA3R, QDL, UL
NF Panelboard Acc. Branch Deadfront Kit 125A, 3 Phase, 54 CCT, Thru Feed Lug
NF Panelboard Acc. Branch Deadfront Kit 125A, 3 Phase, 54 CCT, Thru Feed Lug
Interior, I-Line PNLBRD, hcm, 800 A, main lugs, 32x48x8.25 in
Interior, I-Line PNLBRD, hcm, 800 A, main lugs, 32x48x8.25 in
Panelboard interior, NQ, main breaker, 225A, Cu bus, 42 pole spaces, 3 phase, 4 wire, 240VAC, 48VDC, column width
Panelboard interior, NQ, main breaker, 225A, Cu bus, 42 pole spaces, 3 phase, 4 wire, 240VAC, 48VDC, column width
Trim, I-Line PNLBRD, hcp, flush, 4 pcs, w/door, 42×50 in
Trim, I-Line PNLBRD, hcp, flush, 4 pcs, w/door, 42x50 in
Homeline, QO Wiser expansion kit, 200 A, 120/240 V, 1 PH, 2 pole, incr length
Homeline, QO Wiser expansion kit, 200 A, 120/240 V, 1 PH, 2 pole, incr length
Reviews
There are no reviews yet.