These TeSys VLS disconnect switches are for integration into control systems in applications like material handling, HVAC, pumping, solar energy, mining and many more. This family of disconnect switches has switches ranging from 16A to 125A. The 16A, 25A, 32A, 40A and 63A disconnect switches are UL508 motor disconnect switches rated. The 30A, 63A, 80A, 100A and 125A disconnect switches are UL98 non fusible disconnect switch rated. This fourth pole adder can be added to a VLS3P016R1, VLS3P025R1, VLS3P032R1 or VLS3P040R1 door mount switch. This fourth pole adder for door mounted devices can be mounted on the right or left hand side. This simultaneous closing adder pole has one normally open contact The operational voltage of this fourth pole adder module is 600 Vac 50/60 Hz. This fourth pole adder module has a 40 A current rating. The screw clamp terminals will accept 18 AWG to 6 AWG wire. Fourth pole adder is 3.07 inches tall, 0.47 inches wide and 1.72 inches deep. It weighs 0.09 lbs. This fourth pole adder block is cULus Listed and meets IEC 60947-3 requirements.
Disconnect switch, TeSys VLS, additional pole, 40A, for 16A to 40A switch, size 1, door mount
Disconnect switch, TeSys VLS, additional pole, 40A, for 16A to 40A switch, size 1, door mount
SKU: 172556882
Category: Industrial
Reviews (0)
Be the first to review “Disconnect switch, TeSys VLS, additional pole, 40A, for 16A to 40A switch, size 1, door mount” Cancel reply
Related products
Operating mechanism, flange mounted, variable depth, 30A, 600V, no fuse, switch mechanism, 6 inch handle, NEMA 4X
Operating mechanism, flange mounted, variable depth, 30A, 600V, no fuse, switch mechanism, 6 inch handle, NEMA 4X
Disconnect switch, Tesys VLS, fuse holder, for 3 pole disconnect switch, for up to 32A, 10.3 by 38 mm fuse
Disconnect switch, Tesys VLS, fuse holder, for 3 pole disconnect switch, for up to 32A, 10.3 by 38 mm fuse
Surge protection device, Surgelogic, HWA, 100kA, 600 VAC delta, 3 phase, 3 wire, NEMA 4X
Surge protection device, Surgelogic, HWA, 100kA, 600 VAC delta, 3 phase, 3 wire, NEMA 4X
Surge protection module, Surgelogic, MA, 240kA, 600Y/347 VAC, 3 phase, 4 wire, SPD type 2
Surge protection module, Surgelogic, MA, 240kA, 600Y/347 VAC, 3 phase, 4 wire, SPD type 2
Handles and front plates,TeSys Control,red handle,yellow front,1-3 padlocking,4 screws fixing
Handles and front plates,TeSys Control,red handle,yellow front,1-3 padlocking,4 screws fixing
Additional neutral block,TeSys Control,80A,for V3 / V4
Additional neutral block,TeSys Control,80A,for V3 / V4
Reviews
There are no reviews yet.