TeSys N contactors and starters conform to NEMA ICS2 standards. The NEMA size is printed directly on the face of the contactor. This 3 pole NEMA size 2 nonreversing contactor mounts on 35mm DIN rail and has a 45 amperage continuous current rating. This contactor has 3 HP at 115 VAC and 7.5 HP at 230 VAC single phase ratings. The contactor also has ratings of 10 HP at 200, 15 HP at 230 VAC and 25 HP at 460 and 575 VAC poly phase. The nonreversing contactor is wired for common control with a 24 VDC replaceable coil. Contactor has 1 normally open and 1 normally closed auxiliary contact. This contactor is not in an enclosure. This contactor is 5.47 inches tall, 2.16 inches wide and 4.72 inches deep. It weighs 2.08 lbs. The screw clamp terminals will accept power wires from 16 AWG to 4 AWG and control wires from 16 AWG to 12 AWG. This TeSys N contactor is UL listed and CSA Certified.
Contactor, Tesys N Contactors, nonreversing, 3P, 3phase, 45A, 25HP at 460VAC, NEMA size 2, 24VDC coil, open
Contactor, Tesys N Contactors, nonreversing, 3P, 3phase, 45A, 25HP at 460VAC, NEMA size 2, 24VDC coil, open
SKU: 516112
Category: Starters & Contactors
Reviews (0)
Be the first to review “Contactor, Tesys N Contactors, nonreversing, 3P, 3phase, 45A, 25HP at 460VAC, NEMA size 2, 24VDC coil, open” Cancel reply
Related products
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NO aux., 110VAC coil
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NO aux., 110VAC coil
NEMA starter, Type S, reversing, vertical, Size 3, 90A, 50HP at 575VAC, 5kA SSCR, 3 phase, 3 pole, melting alloy overload, 120VAC coil, open
NEMA starter, Type S, reversing, vertical, Size 3, 90A, 50HP at 575VAC, 5kA SSCR, 3 phase, 3 pole, melting alloy overload, 120VAC coil, open
Contactor TeSys LC1-K – 3 poles – AC-3 440V 9 A – coil 24 V AC
Contactor TeSys LC1-K - 3 poles - AC-3 440V 9 A - coil 24 V AC
Reversing ultra compact starter, TeSys Hybrid, 3P, 500VAC, 0.75kW at 400V, 110 to 230VAC, Spring terminal
Reversing ultra compact starter, TeSys Hybrid, 3P, 500VAC, 0.75kW at 400V, 110 to 230VAC, Spring terminal
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 60 A – 12 V DC standard coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 12 V DC standard coil
TeSys F – specific contactor coil – 110 V AC 40…400 Hz low consumption
TeSys F - specific contactor coil - 110 V AC 40...400 Hz low consumption
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 80 A – 12 V AC 50 Hz coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 80 A - 12 V AC 50 Hz coil
Ambient Compensated Bimetallic Thermal Unit Class 20
Ambient Compensated Bimetallic Thermal Unit Class 20
Reviews
There are no reviews yet.