TeSys N contactors and starters conform to NEMA ICS2 standards. The NEMA size is printed directly on the face of the contactor. This 3 pole NEMA size 0 nonreversing contactor mounts on 35mm DIN rail and has a 18 amperage continuous current rating. This contactor has 1 HP at 115 VAC and 2 HP at 230 VAC single phase ratings. The contactor also has ratings of 3 HP at 200 to 230 VAC and 5 HP at 460 and 575 VAC poly phase. The nonreversing contactor is wired for common control with a 24 VDC replaceable coil. Contactor has 1 normally open and 1 normally closed auxiliary contact. This contactor is not in an enclosure. This contactor is 3.34 inches tall, 1.76 inches wide and 4.00 inches deep. It weighs 1.28 lbs. The screw clamp terminals will accept power wires from 18 AWG to 8 AWG and control wires from 18 AWG to 10 AWG. This TeSys N contactor is UL listed and CSA Certified.
Contactor, Tesys N Contactors, nonreversing, 3P, 3phase, 18A, 5HP at 460VAC, NEMA size 0, 24VDC coil, open
Contactor, Tesys N Contactors, nonreversing, 3P, 3phase, 18A, 5HP at 460VAC, NEMA size 0, 24VDC coil, open
SKU: 509297
Category: Starters & Contactors
Reviews (0)
Be the first to review “Contactor, Tesys N Contactors, nonreversing, 3P, 3phase, 18A, 5HP at 460VAC, NEMA size 0, 24VDC coil, open” Cancel reply
Related products
Contactor, Type S, multipole lighting, electrically held, 400A, 3 pole, 550/600 V 50/60 Hz coil, open style
Contactor, Type S, multipole lighting, electrically held, 400A, 3 pole, 550/600 V 50/60 Hz coil, open style
NEMA starter, Type S, reversing, vertical, Size 3, 90A, 50HP at 575VAC, 5kA SSCR, 3 phase, 3 pole, melting alloy overload, 120VAC coil, open
NEMA starter, Type S, reversing, vertical, Size 3, 90A, 50HP at 575VAC, 5kA SSCR, 3 phase, 3 pole, melting alloy overload, 120VAC coil, open
Reversing ultra compact starter, TeSys Hybrid, 3P, 500VAC, 0.75kW at 400V, 110 to 230VAC, Spring terminal
Reversing ultra compact starter, TeSys Hybrid, 3P, 500VAC, 0.75kW at 400V, 110 to 230VAC, Spring terminal
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 60 A – 12 V DC standard coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 12 V DC standard coil
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 80 A – 12 V AC 50 Hz coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 80 A - 12 V AC 50 Hz coil
TeSys GV7 Manual Starter and Protector, thermal magnetic circuit protector, rocker lever, 3 P, AC-3, 60…100 A, high interrupt
TeSys GV7 Manual Starter and Protector, thermal magnetic circuit protector, rocker lever, 3 P, AC-3, 60...100 A, high interrupt

Reviews
There are no reviews yet.