TeSys N contactors and starters conform to NEMA ICS2 standards. The NEMA size is printed directly on the face of the contactor. This 3 pole NEMA size 0 nonreversing contactor mounts on 35mm DIN rail and has a 18 amperage continuous current rating. This contactor has 1 HP at 115 VAC and 2 HP at 230 VAC single phase ratings. The contactor also has ratings of 3 HP at 200 to 230 VAC and 5 HP at 460 and 575 VAC poly phase. The nonreversing contactor is wired for common control with a 24 VAC 50/60 Hz replaceable coil. Contactor has 1 normally open and 1 normally closed auxiliary contact. This contactor is not in an enclosure. This contactor is 3.34 inches tall, 1.76 inches wide and 3.66 inches deep. It weighs 0.92 lbs. The screw clamp terminals will accept power wires from 18 AWG to 8 AWG and control wires from 18 AWG to 10 AWG. This TeSys N contactor is UL listed and CSA Certified.
NEMA Contactor, TeSys N, nonreversing, Size 0, 18A, 5HP at 460VAC, 3 pole, 3 phase, 24VAC 50/60Hz coil, open
NEMA Contactor, TeSys N, nonreversing, Size 0, 18A, 5HP at 460VAC, 3 pole, 3 phase, 24VAC 50/60Hz coil, open
SKU: 509306
Category: NEMA Contactors & Starters
Reviews (0)
Be the first to review “NEMA Contactor, TeSys N, nonreversing, Size 0, 18A, 5HP at 460VAC, 3 pole, 3 phase, 24VAC 50/60Hz coil, open” Cancel reply
Related products
IEC contactor, TeSys Deca, nonreversing, 80A, 60HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 440VAC 50/60Hz coil, open
IEC contactor, TeSys Deca, nonreversing, 80A, 60HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 440VAC 50/60Hz coil, open
TeSys Deca reversing contactor – 3P(3 NO) – AC-3 – <= 440 V 18 A – 48 V AC coil
TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 48 V AC coil
IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 4 NO, 110VDC coil, open style
IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 4 NO, 110VDC coil, open style
TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 225 A – coil 240 V AC
TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 225 A - coil 240 V AC
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 380VAC 50/60Hz coil, open
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 380VAC 50/60Hz coil, open
TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 115 A – coil 120 V AC
TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 120 V AC
NEMA Combination Starter, Type S, nonfusible disconnect, Size 1, 27A, 10HP at 600VAC, 3 phase, 3 pole, melting alloy, 120VAC coil, NEMA 12
NEMA Combination Starter, Type S, nonfusible disconnect, Size 1, 27A, 10HP at 600VAC, 3 phase, 3 pole, melting alloy, 120VAC coil, NEMA 12
Reviews
There are no reviews yet.