TeSys N contactors and starters conform to NEMA ICS2 standards. The NEMA size is printed directly on the face of the contactor. This 3 pole NEMA size 1 nonreversing contactor mounts on 35mm DIN rail and has a 27 amperage continuous current rating. This contactor has 2 HP at 115 VAC and 3 HP at 230 VAC single phase ratings. The contactor also has ratings of 7.5 HP at 200 to 230 VAC and 10 HP at 460 and 575 VAC poly phase. The nonreversing contactor is wired for common control with a 24 VDC replaceable coil. Contactor has 1 normally open and 1 normally closed auxiliary contact. This contactor is not in an enclosure. This contactor is 3.34 inches tall, 1.76 inches wide and 4.00 inches deep. It weighs 1.28 lbs. The screw clamp terminals will accept power wires from 14 AWG to 6 AWG and control wires from 18 AWG to 10 AWG. This TeSys N contactor is UL listed and CSA Certified.
Contactor, Tesys N Contactors, nonreversing, 3P, 3phase, 27A, 10HP at 460VAC, NEMA size 1, 24VDC coil, open
Contactor, Tesys N Contactors, nonreversing, 3P, 3phase, 27A, 10HP at 460VAC, NEMA size 1, 24VDC coil, open
SKU: 172561497
Category: Automation & Control
Reviews (0)
Be the first to review “Contactor, Tesys N Contactors, nonreversing, 3P, 3phase, 27A, 10HP at 460VAC, NEMA size 1, 24VDC coil, open” Cancel reply
Related products
AC servo motor BSH, Lexium 05, 9.31N.m, 1500rpm, keyed shaft, without brake, IP65
AC servo motor BSH, Lexium 05, 9.31N.m, 1500rpm, keyed shaft, without brake, IP65
variable speed drive, Altivar 212, 18.5kW, 25hp, 240V, 3 phases, without EMC, IP21
variable speed drive, Altivar 212, 18.5kW, 25hp, 240V, 3 phases, without EMC, IP21
interface plug-in relay, Harmony electromechanical relays, 12A, 1CO, 48V AC
interface plug-in relay, Harmony electromechanical relays, 12A, 1CO, 48V AC
Limit switch, Limit switches XC Standard, XCMN, steel roller plunger, 1NC+1 NO, snap, cable
Limit switch, Limit switches XC Standard, XCMN, steel roller plunger, 1NC+1 NO, snap, cable
Non-Reversing Contactor, Size 2, 3-Pole, Open Style +Options
Non-Reversing Contactor, Size 2, 3-Pole, Open Style +Options
Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12…48 VDC, NC, cable 10 m
Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12...48 VDC, NC, cable 10 m
Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
Reviews
There are no reviews yet.