8910DP definite purpose magnetic contactors are designed for heating, air conditioning and refrigeration applications. This line of definite purpose contactors has current ratings up to 120 amperes resistive and 50 HP at 600 VAC. This four pole definite purpose contactor has a full load rating of 20 ampere and a resistive rating of 30 amperes. It also has a 1.5 HP at 115 VAC single phase, 3 HP at 230 VAC single phase and 7.5 HP at 230 VAC and 460 VAC three phase. The nonreplaceable coil is available with a variety of coil voltages. This device has a 208/240 VAC 60 Hz, 220 VAC 50 Hz coil. The contactor has straight through wiring. Contactor has two normally open and two normally closed contacts. Contactor is 3.78 inches by 2.75 inches and 3.04 tall. These contactors are UL component recognized and CSA certified.
Contactor, Definite Purpose, 20A, 4 pole, 7.5 HP at 575 VAC, 3 phase, 208/240 VAC 60 Hz 220 VAC 50 Hz coil, open
Contactor, Definite Purpose, 20A, 4 pole, 7.5 HP at 575 VAC, 3 phase, 208/240 VAC 60 Hz 220 VAC 50 Hz coil, open
SKU: 14495595
Category: Starters & Contactors
Reviews (0)
Be the first to review “Contactor, Definite Purpose, 20A, 4 pole, 7.5 HP at 575 VAC, 3 phase, 208/240 VAC 60 Hz 220 VAC 50 Hz coil, open” Cancel reply
Related products
Ambient Compensated Bimetallic Thermal Unit Class 20
Ambient Compensated Bimetallic Thermal Unit Class 20
NEMA starter, Type S, reversing, vertical, Size 3, 90A, 50HP at 575VAC, 5kA SSCR, 3 phase, 3 pole, melting alloy overload, 120VAC coil, open
NEMA starter, Type S, reversing, vertical, Size 3, 90A, 50HP at 575VAC, 5kA SSCR, 3 phase, 3 pole, melting alloy overload, 120VAC coil, open
Contactor, NIGHT MASTER, combination lighting, 30A, 3 pole, breaker, 24 VAC 60 Hz coil. NEMA 3R
Contactor, NIGHT MASTER, combination lighting, 30A, 3 pole, breaker, 24 VAC 60 Hz coil. NEMA 3R
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NO aux., 110VAC coil
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NO aux., 110VAC coil
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 80 A – 12 V AC 50 Hz coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 80 A - 12 V AC 50 Hz coil
Panelboard lighting contactor auxiliary contact module, top assembly, 1NO-1NC
Panelboard lighting contactor auxiliary contact module, top assembly, 1NO-1NC
Reviews
There are no reviews yet.