PowerPact M-frame molded case circuit breakers provide improved performance and a compact solution for applications up to 800A. They complement the existing PowerPact P- and R-frame circuit breakers and replace the traditional MA/MH circuit breakers with a smaller footprint and competitive cost. PowerPact M-frame molded case circuit breakers are available in 300, 350, 400, 450, 500, 600, 700, and 800A ratings. PowerPact M-frame molded case circuit breakers have built-in electronic trip unit type ET 1.0 provides better accuracy than standard thermal-magnetic trip units. The ET 1.0 trip unit cannot be field replaced, nor does it allow adjustment of the trip point setting. (It is considered an electronic equivalent of a thermal-magnetic circuit breaker.) They also have fIxed long-time and adjustable instantaneous protection (2 to 10 times nominal ampere rating) is standard. Powerpact M-Frame breakers have the same dimensions, common mounting, bussing, cabling and door cut-out as PowerPact P-frame circuit breakers. This PowerPact M, circuit breaker has a rated current of 500A and a rated operational current of 600VAC and is an plug-in mounted breaker. This 2-pole breaker has a breaking capacity of 25kA@600VAC with an 80 % continuous current rating. This breaker complies to UL listed, IEC & CSA standards. This product has an electronic ET 1.0 trip unit trechnology and a magnetic tripping current of 1000-5000A. Dimensions for this product are 12.86 in (H),8.27 in (W), 5.77 in (D). This product comes with an 18 month warranty.
Circuit Breaker, PowerPact M, I-Line, electronic trip, 500A, 2 pole, 25 kA, 600 VAC, lugs load end, AC phasing
Circuit Breaker, PowerPact M, I-Line, electronic trip, 500A, 2 pole, 25 kA, 600 VAC, lugs load end, AC phasing
SKU: 4867488
Category: Circuit Breakers
Reviews (0)
Be the first to review “Circuit Breaker, PowerPact M, I-Line, electronic trip, 500A, 2 pole, 25 kA, 600 VAC, lugs load end, AC phasing” Cancel reply
Related products
Second MX voltage release, MasterPact MTZ1 drawout, remote tripping, 277VAC 50/60Hz
Second MX voltage release, MasterPact MTZ1 drawout, remote tripping, 277VAC 50/60Hz
Circuit breaker, PowerPacT H, 50A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 100%
Circuit breaker, PowerPacT H, 50A, 3 pole, 600VAC, 25kA, lugs, thermal magnetic, 100%
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker frame, MasterPact MTZ2 32H2, 3200A, 100kA/440VAC 50/60Hz (Icu), 4P, drawout, without control unit
Circuit breaker, PowerPacT B, 30A, 3 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 30A, 3 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%
Automatic switch, PowerPacT J, 225A, 3 pole, 600VAC, 50kA, lugs, magnetic
Automatic switch, PowerPacT J, 225A, 3 pole, 600VAC, 50kA, lugs, magnetic
Mini circuit breaker, QOU, 20A, 2 pole, 120/240 VAC, 10kA, mounting foot
Mini circuit breaker, QOU, 20A, 2 pole, 120/240 VAC, 10kA, mounting foot
Circuit breaker, ComPact NSX250H, 70kA/415VAC, TMD trip unit 160A, 3 poles 3d
Circuit breaker, ComPact NSX250H, 70kA/415VAC, TMD trip unit 160A, 3 poles 3d
Circuit breaker, PowerPacT M, 600A, 3 pole, 600VAC, 18kA, lugs, ET 1.0, 80%
Circuit breaker, PowerPacT M, 600A, 3 pole, 600VAC, 18kA, lugs, ET 1.0, 80%
Reviews
There are no reviews yet.