This is an integrated solution for monitoring multi-circuits and mains by using a single meter. The meter is designed for use in new build and is used for critical power operations in data centres and energy management in buildings. It offers class 1 (1 %) power and energy system accuracy (100A solid core current transformers) on all branch channels. The BCPM monitors both the 42 branch circuits and mains values, incoming power and energy. All to provide information on the complete Power Distribution Unit. Full alarming capabilities ensure that potential issues are dealt with before they become problems. Communication enabled with a RS485 serial port and the Modbus protocol support, more communication options with the gateway H8951. The meter need to be powered by a 90V AC to 277V AC supply source. Include 2 21-CTs board strips with 3/4inch (19mm) spacing between each CT connectors, for 42 circuits. The device dimensions are 228mm in width, 146mm in height and weight 1.5 kilograms.
BCPM power monitoring advanced – 42 solid core 100 A – 19 mm CT spacing
BCPM power monitoring advanced – 42 solid core 100 A – 19 mm CT spacing
SKU: 172557842
Category: Automation & Control
Reviews (0)
Be the first to review “BCPM power monitoring advanced – 42 solid core 100 A – 19 mm CT spacing” Cancel reply
Related products
Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
discrete output module Modicon Quantum – 32 O – positive logic (source)
discrete output module Modicon Quantum - 32 O - positive logic (source)
Inductive proximity sensors XS, inductive sensor XS6 M30, L74mm, brass, Sn22mm, 24…240VAC/DC, 1/2″
Inductive proximity sensors XS, inductive sensor XS6 M30, L74mm, brass, Sn22mm, 24...240VAC/DC, 1/2"
TeSys Deca thermal overload relays – 23…32 A – class 10A
TeSys Deca thermal overload relays - 23...32 A - class 10A
Disconnect switch, TeSys VLS, body switch, 100A, 50HP at 480VAC, UL98, three phase, 50kA SCCR, size 2, door mount
Disconnect switch, TeSys VLS, body switch, 100A, 50HP at 480VAC, UL98, three phase, 50kA SCCR, size 2, door mount
Non-Reversing Contactor, Size 2, 3-Pole, Open Style +Options
Non-Reversing Contactor, Size 2, 3-Pole, Open Style +Options
Harmony XB4, Light block with body/fixing collar, metal, blue, integral LED, 24 V AC/DC, 2 NO
Harmony XB4, Light block with body/fixing collar, metal, blue, integral LED, 24 V AC/DC, 2 NO
Reviews
There are no reviews yet.