Homeline All In One combination service entrance devices are available with ring or ringless type meter socket designs. Devices have factory installed service disconnect(s) in most cases. Supplied with 100% branch neutrals, all unused terminals may be used for equipment grounding wires. These Homeline combination service entrance devices meet the Federal Specification W-P-115c as Type 1, Class 2 specifications. This Homeline All In One combination service entrance device has a ringed meter socket with no bypass. This unit can be feed from an overhead or underground service. The service disconnect is a HOM2100 with a maximum rating of 100 A. Device has a 10 kA short circuit current rating. Load center has 16 spaces which will accept up to 8 tandem Homeline circuit breakers. This unit has a NEMA 3R semi flush mount enclosure that is 25.12 inches tall, 14.50 inches wide and 3.39 inches deep. The line side lugs will accept 6 AWG to 2/0 AWG copper or aluminum wire. The service ground lug will accept 6 AWG to 2/0 AWG copper or aluminum wire. This Homeline All In One combination service entrance meter main unit is UL Listed. Device meets EUSERC standards.
All in one, Homeline, combination service entrance, ringed socket, 100 A, semi flush, 16 spaces, 24 circuits, 10kA SSCR, OH, UG, no bypass
All in one, Homeline, combination service entrance, ringed socket, 100 A, semi flush, 16 spaces, 24 circuits, 10kA SSCR, OH, UG, no bypass
SKU: 172554378
Category: Meters & Accessories
Reviews (0)
Be the first to review “All in one, Homeline, combination service entrance, ringed socket, 100 A, semi flush, 16 spaces, 24 circuits, 10kA SSCR, OH, UG, no bypass” Cancel reply
Related products
Branch unit, EZ Meter-Pak, 225A, 5 x 5 jaw sockets, 208Y/120VAC, horn bypass, ringless, 1200A Cu busbar
Branch unit, EZ Meter-Pak, 225A, 5 x 5 jaw sockets, 208Y/120VAC, horn bypass, ringless, 1200A Cu busbar
Branch unit, EZ Meter-Pak, 225A, 2 x 5 sockets, 208Y/120VAC, no bypass, ringless, 1200A Al/Cu busbar
Branch unit, EZ Meter-Pak, 225A, 2 x 5 sockets, 208Y/120VAC, no bypass, ringless, 1200A Al/Cu busbar
Meter mains, QO, CSED, ringed socket, 200A, surface mount, no bypass
Meter mains, QO, CSED, ringed socket, 200A, surface mount, no bypass
ION8650 meter 128MB, FT21 panel, 277VAC 60Hz, Ethernet No I/O
ION8650 meter 128MB, FT21 panel, 277VAC 60Hz, Ethernet No I/O
Branch unit, EZ Meter-Pak, 125A, 6 sockets, 208Y/120VAC, no bypass, ringed, 1200A copper busbar
Branch unit, EZ Meter-Pak, 125A, 6 sockets, 208Y/120VAC, no bypass, ringed, 1200A copper busbar
Main circuit breaker unit, EZ Meter-Pak, 2000A, 120/240VAC, 1ph/3W, 1200A bus, 65kA, UG, Type 3R
Main circuit breaker unit, EZ Meter-Pak, 2000A, 120/240VAC, 1ph/3W, 1200A bus, 65kA, UG, Type 3R
EZ Meter Pak, transition section, right, 1200 A bus, 120/240 VAC single phase
EZ Meter Pak, transition section, right, 1200 A bus, 120/240 VAC single phase