Square D PowerPact H-frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits Molded case circuit breakers are available with either thermal-magnetic or Micrologic electronic trip units. The external neutral current transformer is a required sensor for 3 pole circuit breaker in a system with a distributed neutral to measure the neutral current in oder to protect neutrak conducter and protect against ground faults. This current trasformer could be used with H-frame PowerPacT circuit breakers with current rating 60 to 100A The neutral current transformer is connected in the same way for unit-mount, plug-in or drawout devices, cross-sectional area is AWG 22-AWG 16.
Circuit breaker accessory, PowerPacT H, Micrologic, external neutral current transformer, ENCT, 60A to 100A
Circuit breaker accessory, PowerPacT H, Micrologic, external neutral current transformer, ENCT, 60A to 100A
SKU: 8985963
Category: Power Distribution
Reviews (0)
Be the first to review “Circuit breaker accessory, PowerPacT H, Micrologic, external neutral current transformer, ENCT, 60A to 100A” Cancel reply
Related products
Circuit breaker, PowerPacT B, 100A, 3 pole, 480Y/277VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Circuit breaker, PowerPacT B, 100A, 3 pole, 480Y/277VAC, 18kA, I-Line, thermal magnetic, 80%, ABC
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Miniature circuit breaker (MCB), Multi9 C60H, 2P, 16A, C curve, 15kA (IEC/EN 60947-2)
Miniature circuit breaker (MCB), Multi9 C60H, 2P, 16A, C curve, 15kA (IEC/EN 60947-2)
Mini circuit breaker, QO, 15A, 1 pole, 120VAC, 10kA, plug in, dual function, pigtail
Mini circuit breaker, QO, 15A, 1 pole, 120VAC, 10kA, plug in, dual function, pigtail
Circuit breaker accessory, PowerPacT L, lug kit, compression, 600A, 3 pole, aluminum at 620A
Circuit breaker accessory, PowerPacT L, lug kit, compression, 600A, 3 pole, aluminum at 620A
Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0A, 80%
Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0A, 80%
Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 14kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT J, 250A, 3 pole, 600VAC, 14kA, lugs, thermal magnetic, 80%
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Reviews
There are no reviews yet.