Square D LA molded case circuit breakers provide thermal magnetic protection. Their primary function is automatic opening of a circuit under overload or short circuit conditions or manual opening. LA circuit breakers contain thermal (overload) and magnetic (short circuit) sensing elements in each pole. Push-to-Trip allows the circuit breaker to be manually tripped without exposure to live parts. This Square D LA molded case circuit breaker is a 3 pole unit mount breaker, 350A and 600VAC, with lugs. The thermal magnetic circuit breaker has an interrupting rating of 22kA for 600VAC and 10kA for 250VDC. LA breakers are UL 489, CSA, IEC certified.
Circuit breaker, LA, 350A, 3 pole, 600VAC, 22kA, 250VDC, 10kA, lugs, thermal magnetic
Circuit breaker, LA, 350A, 3 pole, 600VAC, 22kA, 250VDC, 10kA, lugs, thermal magnetic
SKU: 1358353
Category: Circuit Breakers
Reviews (0)
Be the first to review “Circuit breaker, LA, 350A, 3 pole, 600VAC, 22kA, 250VDC, 10kA, lugs, thermal magnetic” Cancel reply
Related products
Miniature circuit breaker (MCB), Multi9 C60BP, 1P, 5A, D curve, 14kA (UL489), 10kA (IEC/EN 60947-2)
Miniature circuit breaker (MCB), Multi9 C60BP, 1P, 5A, D curve, 14kA (UL489), 10kA (IEC/EN 60947-2)
Circuit breaker, PowerPacT B, 125A, 1 pole, 600Y/347VAC, 14kA, I-Line, thermal magnetic, 80%, C
Circuit breaker, PowerPacT B, 125A, 1 pole, 600Y/347VAC, 14kA, I-Line, thermal magnetic, 80%, C
Mini circuit breaker, QO, 20A, 3 pole, 240VAC, 10kA, 100mA grd fault B, bolt on mount, ring
Mini circuit breaker, QO, 20A, 3 pole, 240VAC, 10kA, 100mA grd fault B, bolt on mount, ring
Circuit breaker, PowerPacT P, I-Line, Micrologic 5.0, 400A, 3 pole, 25kA, 600VAC, phase ABC, shunt trip, 80% rated
Circuit breaker, PowerPacT P, I-Line, Micrologic 5.0, 400A, 3 pole, 25kA, 600VAC, phase ABC, shunt trip, 80% rated
Circuit breaker, ComPact NSX250H, 70kA/415VAC, TMD trip unit 160A, 3 poles 3d
Circuit breaker, ComPact NSX250H, 70kA/415VAC, TMD trip unit 160A, 3 poles 3d
Miniature circuit breaker (MCB), Multi9 C60N, 4P, 4A, C curve, 10kA (IEC/EN 60947-2)
Miniature circuit breaker (MCB), Multi9 C60N, 4P, 4A, C curve, 10kA (IEC/EN 60947-2)
Circuit breaker, PowerPacT H, 100A, 3 pole, 600VAC, 50kA, I-Line, Micrologic 5.2E, 80%, ABC
Circuit breaker, PowerPacT H, 100A, 3 pole, 600VAC, 50kA, I-Line, Micrologic 5.2E, 80%, ABC
Motor circuit protector, PowerPacT H, unit mount, 30A, 3 pole, 25kA, 600 VAC, auxiliary switch, copper lugs, 80% rated
Motor circuit protector, PowerPacT H, unit mount, 30A, 3 pole, 25kA, 600 VAC, auxiliary switch, copper lugs, 80% rated
Reviews
There are no reviews yet.