Type S NEMA motor starters are used for full voltage starting and stopping of AC squirrel cage motors. Type S motor starters have ratings up to 810 amperes. This 2 pole NEMA Size 00 non-reversing starter has an 9 ampere rating. This NEMA Size 00 motor starter has single phase ratings of 0.33 HP at 115 VAC and 1 HP at 230 VAC. This non-reversing NEMA motor starter has a melting alloy type overload relay that uses Type B thermal units to sense over current conditions. This NEMA starter has a 5 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 110/120 VAC 50/60 Hz operating coil wired for common control. A painted sheet steel NEMA 1 general purpose enclosure is used to protect this starter. Enclosure is 10.00 inches tall, 6.00 inches wide and 5.56 inches deep. A wide variety of accessories are available for Type S starters. Type S non-reversing NEMA motor starters are UL listed and CSA certified.
NEMA Motor Starter, Type S, nonreversing, Size 00, 9A, 1 HP at 230 VAC, 5 kA SSCR, 1 phase, 2 pole, melting alloy, 120 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 00, 9A, 1 HP at 230 VAC, 5 kA SSCR, 1 phase, 2 pole, melting alloy, 120 VAC coil, NEMA 1
SKU: 4871913
Category: NEMA Contactors & Starters
Reviews (0)
Be the first to review “NEMA Motor Starter, Type S, nonreversing, Size 00, 9A, 1 HP at 230 VAC, 5 kA SSCR, 1 phase, 2 pole, melting alloy, 120 VAC coil, NEMA 1” Cancel reply
Related products
TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 225 A – coil 240 V AC
TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 225 A - coil 240 V AC
Thermal Unit, Type S, Type CC, melting alloy, Class 20
Thermal Unit, Type S, Type CC, melting alloy, Class 20
NEMA combination starter, Type S, fusible disconnect, fuse clip kit, class R fuse, 60A, 600 V, NEMA 2 or 60A contactor
NEMA combination starter, Type S, fusible disconnect, fuse clip kit, class R fuse, 60A, 600 V, NEMA 2 or 60A contactor
TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 115 A – coil 120 V AC
TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 120 V AC
TeSys Deca reversing contactor – 3P(3 NO) – AC-3 – <= 440 V 12 A – 24 V DC coil
TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil
IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 4 NO, 110VDC coil, open style
IEC contactor, TeSys Deca, nonreversing, 20A resistive, 4 pole, 4 NO, 110VDC coil, open style
NEMA Motor Starter, Type S, nonreversing, Size 5, 270A, 200 HP at 460 VAC, 3 phase, 3 pole, melting alloy, 120 VAC coil, open, 10 kA SSCR
NEMA Motor Starter, Type S, nonreversing, Size 5, 270A, 200 HP at 460 VAC, 3 phase, 3 pole, melting alloy, 120 VAC coil, open, 10 kA SSCR
Thermal Unit, Type S, Type B, melting alloy, Class 20
Thermal Unit, Type S, Type B, melting alloy, Class 20
Reviews
There are no reviews yet.