8911 definite purpose starters are inexpensive starters for applications with relatively low duty cycles. Typical applications include air compressors, agricultural equipment, pumps, and HVAC equipment. This three pole definite purpose starter has a full load rating of 50 amperes. This starter has ratings of 3 HP at 115 VAC and 10 HP at 230 VAC single phase. It has a 15 HP at 230 VAC, 30 HP at 460 VAC and at 575 VAC three phase. The nonreplaceable coil is available with a variety of coil voltages. This device has a 220/208 to 240 VAC 50/60 Hz coil. The starter has straight through wiring. The melting alloy type overload relay uses Type B thermal units to sense over current conditions. This definite purpose contactor is an open device without an enclosure. Enclosure is 6.73 inches tall, 3.50 inches wide and 4.09 inches deep. Auxiliary contacts are available for these starters. 8911DPS definite purpose starters are UL component recognized.
NEMA Starter, Definite Purpose, 50A, 30HP at 600VAC, 3 phase, 3 pole, melting alloy, 208V to 240VAC coil, open
NEMA Starter, Definite Purpose, 50A, 30HP at 600VAC, 3 phase, 3 pole, melting alloy, 208V to 240VAC coil, open
SKU: 13485286
Category: Starters & Contactors
Reviews (0)
Be the first to review “NEMA Starter, Definite Purpose, 50A, 30HP at 600VAC, 3 phase, 3 pole, melting alloy, 208V to 240VAC coil, open” Cancel reply
Related products
Switch, manual, 30A, 3 pole, 10 HP at 575 VAC, three phase, toggle operated, no indicator, open style
Switch, manual, 30A, 3 pole, 10 HP at 575 VAC, three phase, toggle operated, no indicator, open style
Contactor, Type L, multipole lighting, mechanically held, 30A, 6 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 1, +option
Contactor, Type L, multipole lighting, mechanically held, 30A, 6 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 1, +option
Contactor, Type S, multipole lighting, electrically held, 400A, 3 pole, 550/600 V 50/60 Hz coil, open style
Contactor, Type S, multipole lighting, electrically held, 400A, 3 pole, 550/600 V 50/60 Hz coil, open style
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V, 6A, 1 NO aux, 12VDC coil
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V, 6A, 1 NO aux, 12VDC coil
Contactor, Type L, multipole lighting, mechanically held, 30A, 3 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 3R/12
Contactor, Type L, multipole lighting, mechanically held, 30A, 3 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 3R/12
NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 2 phase, 4 pole, melting alloy, 240 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 2 phase, 4 pole, melting alloy, 240 VAC coil, NEMA 1
Contactor, TeSys K, 4P, 4 NO, ,AC-1, lt or eq to 440V, 20A, 24VDC coil
Contactor, TeSys K, 4P, 4 NO, ,AC-1, lt or eq to 440V, 20A, 24VDC coil