PowerPact B-frame circuit breaker, BGL16045, offers proven performance, flexibility, and reliability. This PowerPact Molded Case Circuit Breaker feature new innovations such as the patented EverLink™ connections. PowerPact B-frame circuit breakers provides economical thermal magnetic circuit protection with a breaking capacity of 25kA at 220 – 240 VAC50/60 Hz. Certified to UL, NEMA, IEC, CSA, NMX, GB Standards. Dimensions are 137 mm (H) x27 mm (W) x 80 mm (D) and weighs 0.46 kg. PowerPact B-frame ratings and types. Available in 1, 2, 3, and 4-pole unit mount construction & 1, 2, and 3-pole I-Line™ construction. Cost-effective fixed thermal-magnetic trip units from 15-125A up to 600Y/347 Vac. Interrupting ratings include D-18 kA, G-35 kA, and J-65 kA at 480 Vac. Unique I-Line construction mounts into Square D™ panelboards and switchboards. Designed to the same 1.5″ per pole widths as the legacy F-frame, simplifying substitution without blank fillers. Unit mount (aka, lug-lug) construction is 30% smaller in size with 25% more capacity than the legacy unit-mount F-frame design EverLink atented technology. EverLink lug connectors reduce the loosening of cables over time using a spring tension design. EverLink lugs are rated for bare use with fine-stranded conductors up to Class K. EverLink lugs are also available with unique integrated control wire terminals.
Circuit breaker, PowerPact B, 45A, 1 pole, 600Y/347V AC, 18kA at 600Y/347 UL, EverLink lugs both ends
Circuit breaker, PowerPact B, 45A, 1 pole, 600Y/347V AC, 18kA at 600Y/347 UL, EverLink lugs both ends
SKU: 9016026
Category: Power Distribution
Reviews (0)
Be the first to review “Circuit breaker, PowerPact B, 45A, 1 pole, 600Y/347V AC, 18kA at 600Y/347 UL, EverLink lugs both ends” Cancel reply
Related products
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Mini CB, QO, 20 A, 2P, 120 V, 10 kA, Plug in, SWN, 50Deg
Mini CB, QO, 20 A, 2P, 120 V, 10 kA, Plug in, SWN, 50Deg
QOU Miniature Circuit Breaker, 20A, 2P, 120/240V, 10kA, Aux Switch
QOU Miniature Circuit Breaker, 20A, 2P, 120/240V, 10kA, Aux Switch
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Three Low-level MTZ2,3 CT Test Position Push in Carriage Switches
Transformer disconnect, 2000VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 2000VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Acti 9 – comb busbar – 3L+N balanced – 9 mm pitch – 12 modules – 80A
Acti 9 - comb busbar - 3L+N balanced - 9 mm pitch - 12 modules - 80A
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1