TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 32A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 7.5HP at 200 to 208VAC, 10HP at 240VAC, 20HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 80A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a low consumption 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.98 inches deep. It weighs 1.18 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, low consumption 24VDC coil
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, low consumption 24VDC coil
SKU: 504099
Category: Starters & Contactors
Reviews (0)
Be the first to review “IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, low consumption 24VDC coil” Cancel reply
Related products
TeSys F – specific contactor coil – 110 V AC 40…400 Hz low consumption
TeSys F - specific contactor coil - 110 V AC 40...400 Hz low consumption
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 110/120 VAC 50/60 Hz coil, open style
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 110/120 VAC 50/60 Hz coil, open style
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NC aux., 24VAC coil
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NC aux., 24VAC coil
Ambient Compensated Bimetallic Thermal Unit Class 20
Ambient Compensated Bimetallic Thermal Unit Class 20
Contactor, NIGHT MASTER, combination lighting, 30A, 3 pole, breaker, 24 VAC 60 Hz coil. NEMA 3R
Contactor, NIGHT MASTER, combination lighting, 30A, 3 pole, breaker, 24 VAC 60 Hz coil. NEMA 3R
Non-Reversing Contactor, Size 2, 2-Pole, Open Style +Options
Non-Reversing Contactor, Size 2, 2-Pole, Open Style +Options
NEMA Contactor and NEMA Motor Starter, Type S, nonreversing, enclosure, NEMA Size 00, 0, 1, 8903SM lighting, NEMA 3R
NEMA Contactor and NEMA Motor Starter, Type S, nonreversing, enclosure, NEMA Size 00, 0, 1, 8903SM lighting, NEMA 3R
Contactor, Type S, multipole lighting, mechanically held, 200A, 2 pole, 440/480 VAC 50/60 Hz coil, NEMA 12
Contactor, Type S, multipole lighting, mechanically held, 200A, 2 pole, 440/480 VAC 50/60 Hz coil, NEMA 12
Reviews
There are no reviews yet.