GV7RE150 is a TeSys GV7R motor circuit breaker from Schneider Electric. It ensures thermal-magnetic protection for motors 55-75kW@400V with breaking capacity Icu 35kA. Start-stop control by rocker lever guaranteed for 20 000 cycles AC-3 415V. GV7RE150 is a TeSys GV7R motor circuit breaker from Schneider Electric designed for motor applications 55-75kW@400V. It fulfills thermal-magnetic protection with a thermal setting range 90-150A, magnetic tripping at 12-14xIn and breaking capacity Icu 35kA@400V. Start-stop control by rocker lever guaranteed for 20 000 cycles AC-3 415V. Available worldwide, it is multi-standards certified (IEC, UL, CSA, Marine). Complete motor protection in a single device , short-circuit, overload, disconnection. Associated with a TeSys contactor, it ensures a complete type 1 or type 2 Motor Starter solution. For industrial or building LV distribution networks thanks to 35kA breaking capacity. Power connections with screw clamp terminals. Manual control with rocker lever for Start / Stop, padlockable with accessory (GV7V). Possible integration of auxiliary contacts (GV7AB, GV7AD, GV7AE) for status and tripping signaling. Possible integration of undervoltage or shunt tripping units (GV7AU, GV7AS).
TeSys GV7 Manual Starter and Protector, thermal magnetic circuit protector, rocker lever, 3 P, AC-3, 90…150 A
TeSys GV7 Manual Starter and Protector, thermal magnetic circuit protector, rocker lever, 3 P, AC-3, 90…150 A
SKU: 502667
Category: Starters & Contactors
Reviews (0)
Be the first to review “TeSys GV7 Manual Starter and Protector, thermal magnetic circuit protector, rocker lever, 3 P, AC-3, 90…150 A” Cancel reply
Related products
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 60 A – 12 V DC standard coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 12 V DC standard coil
Contactor, Type L, multipole lighting, electrically held, 30A, 2 pole, 600 V, 277 VAC 60 Hz coil, NEMA 1
Contactor, Type L, multipole lighting, electrically held, 30A, 2 pole, 600 V, 277 VAC 60 Hz coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 2, 45A, 25 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 24 VAC coil, NEMA 4X
NEMA Motor Starter, Type S, nonreversing, Size 2, 45A, 25 HP at 460 VAC, 5 kA SCCR, 3 phase, 3 pole, melting alloy, 24 VAC coil, NEMA 4X
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 80 A – 12 V AC 50 Hz coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 80 A - 12 V AC 50 Hz coil
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
Contactor, Type L, multipole lighting, mechanically held, 30A, 6 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 1, +option
Contactor, Type L, multipole lighting, mechanically held, 30A, 6 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 1, +option
Contactor, Definite Purpose, 25A, 2 pole, 110/120 VAC 50/60 Hz coil, open, with cover
Contactor, Definite Purpose, 25A, 2 pole, 110/120 VAC 50/60 Hz coil, open, with cover
Reviews
There are no reviews yet.