PowerPacT H-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT H-Frame circuit breakers are available with either thermal magnetic or Micrologic electronic trip protection units. This PowerPacT H-Frame circuit breaker provides thermal magnetic circuit protection with a breaking capacity of 50kA at 600VAC. All PowerPacT H-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT H circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. PowerPacT H I-Line circuit breakers are available in I-Line construction for easy installation and removal in I-Line applications. This breaker has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT H, 35A, 2 pole, circuit breaker has a breaking capacity of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80% with a BA phase connection. PowerPacT H circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
Circuit breaker, PowerPacT H, 35A, 2 pole, 600VAC, 50kA, I-Line, thermal magnetic, 80%, BA
Circuit breaker, PowerPacT H, 35A, 2 pole, 600VAC, 50kA, I-Line, thermal magnetic, 80%, BA
SKU: 16941092
Category: Power Distribution
Reviews (0)
Be the first to review “Circuit breaker, PowerPacT H, 35A, 2 pole, 600VAC, 50kA, I-Line, thermal magnetic, 80%, BA” Cancel reply
Related products
Transformer disconnect, 2000VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 2000VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Multi 9 – C60H – MCB – 4P – 63 A – D Curve – 415 V – 15 kA
Multi 9 - C60H - MCB - 4P - 63 A - D Curve - 415 V - 15 kA
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Transformer, Type T, industrial control, 75VA, 1 phase, 208V primary, 120V secondary, 55C rise
Circuit breaker frame, MasterPact MTZ2 12H1, 1250A, 66kA/440VAC 50/60Hz (Icu), 3P, fixed, without control unit
Circuit breaker frame, MasterPact MTZ2 12H1, 1250A, 66kA/440VAC 50/60Hz (Icu), 3P, fixed, without control unit
Multi 9 – C60 UL489 – MCB – 3P – 4 A – D Curve – 480Y/277 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 4 A - D Curve - 480Y/277 V - 10 kA - ring term
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Reviews
There are no reviews yet.