PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn’t have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has terminal nuts on the line side and lugs on the load side. This PowerPacT P, 600A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
Circuit breaker, PowerPacT P, 600A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0, 100%
Circuit breaker, PowerPacT P, 600A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0, 100%
SKU: 4278227
Category: Power Distribution
Reviews (0)
Be the first to review “Circuit breaker, PowerPacT P, 600A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0, 100%” Cancel reply
Related products
Multi 9 – C60 UL489 – MCB – 3P – 13 A – D Curve – 240 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 13 A - D Curve - 240 V - 10 kA - ring term
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Transformer disconnect, 1500VA, 240x480VAC primary, 120VAC secondary, with outlet, Type 1
Circuit breaker, PowerPacT H, 45A, 3 pole, 600VAC, 18kA, I-Line, thermal magnetic, 80%, CBA
Circuit breaker, PowerPacT H, 45A, 3 pole, 600VAC, 18kA, I-Line, thermal magnetic, 80%, CBA
Mini CB, QO, 20 A, 2P, 120 V, 10 kA, Plug in, SWN, 50Deg
Mini CB, QO, 20 A, 2P, 120 V, 10 kA, Plug in, SWN, 50Deg
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Circuit Breaker Masterpact MTZ2 20H2 ANSI-2000A-4P drawout-w/o Micrologic
Circuit breaker, PowerPacT B, 60A, 3 pole, 600Y/347VAC, 18kA, lugs, thermal magnetic, 80%
Circuit breaker, PowerPacT B, 60A, 3 pole, 600Y/347VAC, 18kA, lugs, thermal magnetic, 80%
Reviews
There are no reviews yet.