TeSys GV manual self protected combination starters meet the requirements of UL 508 Type F, see UL File E164871. Manual motor starter consists of a GV2 motor starter protector and a LC1D IEC contactor assembled together into one device. This enclosure is for GV2ME manual starters and protectors with or without accessories Enclosure is flush mounting with front face reduced. Auxiliary contacts can only be added on the right hand side of the GV2ME. The enclosure rating is NEMA 1 and IP41. Enclosure is 5.24 inches tall, 3.66 inches wide and 3.86 inches deep. This enclosure is not UL listed, but is CSA certified.
TeSys GV2 motor starter, reduced flush mounting enclosure, for TeSys GV2ME, NEMA 1 and IP41
TeSys GV2 motor starter, reduced flush mounting enclosure, for TeSys GV2ME, NEMA 1 and IP41
SKU: 503875
Category: Starters & Contactors
Reviews (0)
Be the first to review “TeSys GV2 motor starter, reduced flush mounting enclosure, for TeSys GV2ME, NEMA 1 and IP41” Cancel reply
Related products
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NO aux., 110VAC coil
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NO aux., 110VAC coil
NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 2 phase, 4 pole, melting alloy, 240 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 2 phase, 4 pole, melting alloy, 240 VAC coil, NEMA 1
NEMA Contactor, Type S, reversing, horizontal, Size 00, 9A, 1 HP at 230 VAC, single phase, up to 100 kA, 2 pole, 208 VAC coil, open style
NEMA Contactor, Type S, reversing, horizontal, Size 00, 9A, 1 HP at 230 VAC, single phase, up to 100 kA, 2 pole, 208 VAC coil, open style
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
NEMA Contactor, Type S, nonreversing, Size 1, 27A, 10 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 120 VAC coil, open
NEMA Contactor, Type S, nonreversing, Size 1, 27A, 10 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 120 VAC coil, open
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NC aux., 24VAC coil
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NC aux., 24VAC coil

Reviews
There are no reviews yet.