TeSys N contactors and starters conform to NEMA ICS2 standards. The NEMA size is printed directly on the face of the contactor. The 3 pole NEMA size 0 contactor has an 18 amperage continuous current rating. It also has ratings of 3 HP at 200 to 230 Vac and 5 HP at 460 and 575 VAC poly phase. The contactor has a 120 VAC replaceable coil with common control. Contactor has 1 normally open and 1 normally closed auxiliary contact. This contactor is not in an enclosure. Contactor is UL listed and CSA Certified. This contactor is 3.34 inches tall, 1.76 inches wide and 3.66 inches deep. It weighs 0.91 lbs. The screw clamp terminals will accept power wires from 18 AWG to 8 AWG and control wires from 18 AWG to 10 AWG. This TeSys N contactor is UL listed and CSA Certified.
Contactor, Tesys N Contactors, nonreversing, 3P, 3phase, 18A, 5HP at 460VAC, NEMA size 0, 120VAC 50/60Hz coil, open
Contactor, Tesys N Contactors, nonreversing, 3P, 3phase, 18A, 5HP at 460VAC, NEMA size 0, 120VAC 50/60Hz coil, open
SKU: 513542
Category: NEMA Contactors & Starters
Reviews (0)
Be the first to review “Contactor, Tesys N Contactors, nonreversing, 3P, 3phase, 18A, 5HP at 460VAC, NEMA size 0, 120VAC 50/60Hz coil, open” Cancel reply
Related products
NEMA Contactor and NEMA Motor Starter, Type S, replacement contact kit, 8502SG, 8536SG, 8903SX, NEMA size 5, 300A, 3 pole
NEMA Contactor and NEMA Motor Starter, Type S, replacement contact kit, 8502SG, 8536SG, 8903SX, NEMA size 5, 300A, 3 pole
TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 115 A – coil 120 V AC
TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 120 V AC
NEMA Contactor, Type S, nonreversing, Size 3, 90A, 50HP at 575VAC, 3 phase, up to 100kA, 3 pole, 120VAC coil, NEMA 1
NEMA Contactor, Type S, nonreversing, Size 3, 90A, 50HP at 575VAC, 3 phase, up to 100kA, 3 pole, 120VAC coil, NEMA 1
Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NO, 48VAC coil
Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NO, 48VAC coil
TeSys Deca reversing contactor – 3P(3 NO) – AC-3 – <= 440 V 18 A – 24 V AC coil
TeSys Deca reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 18 A - 24 V AC coil
IEC contactor, TeSys Deca, nonreversing, 12A, 7.5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open
IEC contactor, TeSys Deca, nonreversing, 12A, 7.5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open
IEC contactor, TeSys Deca, nonreversing, 9A, 5HP at 480VAC, 3 phase, 3 pole, 3 NO, 110VAC 50/60Hz coil, open style
IEC contactor, TeSys Deca, nonreversing, 9A, 5HP at 480VAC, 3 phase, 3 pole, 3 NO, 110VAC 50/60Hz coil, open style
TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 115 A – coil 380 V AC
TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 380 V AC