NQ Panelboard interiors can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices. NQ Panelboards are versatile panelboards that feature a wide selection of circuit breakers, accessories, and ready to install kits. NQ Panelboard interiors are field convertible to top or bottom feed. NQ Panelboards are convertible from main lug to main breaker. NQ Panelboards provide 200% rated neutrals for nonlinear loads. Some factory installed options are split bus, lighting contactors, compression lugs, surge protection devices, and phenolic nameplates. This interior provides protection for your commercial and industrial applications. The main lugs are rated at 225A, 240 VAC single phase or 48 VDC. Interior has an interrupt current rating of up to 65 kA. This interior is for a 3 wire system with 42 spaces and has a copper bus bar. Interior is for QOB, QOBVH and QHB branch circuit breakers. Lug connections will accept 6 AWG to 350 kcmil copper or aluminum wire. Interior is 58 inches tall and 8.63 inches wide. This NQ panelboard interior is UL listed and CSA certified.
Panelboard interior, NQ, main lugs, 225A, Cu bus, 42 pole spaces, 1 phase, 3 wire, 240VAC, 48VDC, 14in
Panelboard interior, NQ, main lugs, 225A, Cu bus, 42 pole spaces, 1 phase, 3 wire, 240VAC, 48VDC, 14in
SKU: 2983409
Category: Load Centers & Panel Boards
Reviews (0)
Be the first to review “Panelboard interior, NQ, main lugs, 225A, Cu bus, 42 pole spaces, 1 phase, 3 wire, 240VAC, 48VDC, 14in” Cancel reply
Related products
Interior, I-Line Panelboard, HCP, 800A, w/main breaker, 72in CB space, for 42in W x 86in H x 9.5in D box, Cu bus
Interior, I-Line Panelboard, HCP, 800A, w/main breaker, 72in CB space, for 42in W x 86in H x 9.5in D box, Cu bus
Panelboard accessory, NQ, lug kit, compression, 100A, 8 to 1/0 AWG, Al
Panelboard accessory, NQ, lug kit, compression, 100A, 8 to 1/0 AWG, Al
Panelboard enclosure cover, NQ, NEMA 1, flush, 15.52in W x 39.52in H
Panelboard enclosure cover, NQ, NEMA 1, flush, 15.52in W x 39.52in H
NF Panelboard Acc. Branch Deadfront Kit 125A, 3 Phase, 54 CCT, Thru Feed Lug
NF Panelboard Acc. Branch Deadfront Kit 125A, 3 Phase, 54 CCT, Thru Feed Lug
Mini circuit breaker, E-Frame, 20A, 2 pole, 480Y/277 VAC, 100 kA max, bolt on, shunt trip
Mini circuit breaker, E-Frame, 20A, 2 pole, 480Y/277 VAC, 100 kA max, bolt on, shunt trip
Load center, QO, 3 phase, 42 spaces, 42 circuits, 125A convertible main breaker, NEMA3R, QDL, UL
Load center, QO, 3 phase, 42 spaces, 42 circuits, 125A convertible main breaker, NEMA3R, QDL, UL
QO LoadCenter, Main Breaker, 200A, 1PH-3W, 30SP, NEMA 1, Ftry. Gnd.Bar
QO LoadCenter, Main Breaker, 200A, 1PH-3W, 30SP, NEMA 1, Ftry. Gnd.Bar
Trim, I-Line PNLBRD, hcp, flush, 4 pcs, w/door, 42×50 in
Trim, I-Line PNLBRD, hcp, flush, 4 pcs, w/door, 42x50 in