8911 definite purpose starters are inexpensive starters for applications with relatively low duty cycles. Typical applications include air compressors, agricultural equipment, pumps, and HVAC equipment. This three pole definite purpose starter has a full load rating of 20 amperes. This starter has ratings of 1.5 HP at 115 VAC and 3 HP at 230 VAC single phase. It has a 7.5 HP at 230 VAC, 460 VAC and 575 VAC poly phase. The nonreplaceable coil is available with a variety of coil voltages. This device has a 208 to 240 VAC 60 HZ and 220 VAC 50 Hz coil. The starter has straight through wiring. The melting alloy type overload relay uses Type B thermal units to sense over current conditions. A painted sheet steel NEMA 1 general purpose enclosure is used to protect this definite purpose starter. Enclosure is 10.00 inches tall, 6.00 inches wide and 5.56 inches deep. Auxiliary contacts are available for these starters. 8911DPS definite purpose starters are UL component recognized.
Starter, Definite Purpose, nonreversing, 20A, 3 pole, 3 phase, 208V to 240V AC coil, melting alloy overload, NEMA 1
Starter, Definite Purpose, nonreversing, 20A, 3 pole, 3 phase, 208V to 240V AC coil, melting alloy overload, NEMA 1
SKU: 15718797
Category: Starters & Contactors
Reviews (0)
Be the first to review “Starter, Definite Purpose, nonreversing, 20A, 3 pole, 3 phase, 208V to 240V AC coil, melting alloy overload, NEMA 1” Cancel reply
Related products
TeSys F – specific contactor coil – 110 V AC 40…400 Hz low consumption
TeSys F - specific contactor coil - 110 V AC 40...400 Hz low consumption
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 80 A – 12 V AC 50 Hz coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 80 A - 12 V AC 50 Hz coil
NEMA Contactor, Type S, nonreversing, Size 1, 27A, 10 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 120 VAC coil, open
NEMA Contactor, Type S, nonreversing, Size 1, 27A, 10 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 120 VAC coil, open
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 277 VAC 60 Hz coil, NEMA 1, +option
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 277 VAC 60 Hz coil, NEMA 1, +option
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NO aux., 110VAC coil
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NO aux., 110VAC coil
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
NEMA starter, Type S, reversing, vertical, Size 3, 90A, 50HP at 575VAC, 5kA SSCR, 3 phase, 3 pole, melting alloy overload, 120VAC coil, open
NEMA starter, Type S, reversing, vertical, Size 3, 90A, 50HP at 575VAC, 5kA SSCR, 3 phase, 3 pole, melting alloy overload, 120VAC coil, open
Reviews
There are no reviews yet.