8965 reversing hoist contactors are designed for control of hoists, overhead doors, small elevators and commercial laundry equipment. They are rated to perform in the short periods of jogging experienced in hoist service. This 3 pole contactor has ratings of 1 HP at 115 VAC and 1.5 HP at 230 VAC single phase. Has ratings of 5 HP at 230 HP and 7.5 HP at 460 VAC and 575 VAC poly phase. These contactors must be mounted upright on the vertical plane. The contactors will not operate properly when mounted in any other position. The replaceable coil is available with a variety of coil voltages. This device has a 24 VAC 60 Hz coil. The power terminals have quick connect terminals. This device is with jumper straps. This reversing contactor doesn’t have an enclosure. Reversing contactor is 3.31 inches tall, 3.31 inches wide and 3.03 inches deep. Auxiliary contacts are available for these contactors. 8965RO reversing hoist contactors are UL component recognized and CSA certified.
Contactor, 8965RO, hoist, reversing, 3HP at 480VAC, 3 phase, 24VAC coil, quick connect terminals. open style
Contactor, 8965RO, hoist, reversing, 3HP at 480VAC, 3 phase, 24VAC coil, quick connect terminals. open style
SKU: 1349467
Category: Starters & Contactors
Reviews (0)
Be the first to review “Contactor, 8965RO, hoist, reversing, 3HP at 480VAC, 3 phase, 24VAC coil, quick connect terminals. open style” Cancel reply
Related products
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 2 phase, 4 pole, melting alloy, 240 VAC coil, NEMA 1
NEMA Motor Starter, Type S, nonreversing, Size 3, 90A, 50 HP at 460 VAC, 5 kA SCCR, 2 phase, 4 pole, melting alloy, 240 VAC coil, NEMA 1
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NO aux., 110VAC coil
Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NO aux., 110VAC coil
Contactor, NIGHT MASTER, combination lighting, 30A, 3 pole, breaker, 24 VAC 60 Hz coil. NEMA 3R
Contactor, NIGHT MASTER, combination lighting, 30A, 3 pole, breaker, 24 VAC 60 Hz coil. NEMA 3R
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 60 A – 12 V DC standard coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 12 V DC standard coil
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
Contactor, Type S, combination lighting, electrically held, 30A, 3 pole, breaker, 440/480 VAC 50/60 Hz coil, NEMA 1
Ambient Compensated Bimetallic Thermal Unit Class 20
Ambient Compensated Bimetallic Thermal Unit Class 20

Reviews
There are no reviews yet.