GV7RS40 is a TeSys GV7R motor circuit breaker from Schneider Electric. It ensures thermal-magnetic protection for motors 15-18.5kW@400V with high breaking capacity Icu 70kA. Start-stop control by rocker lever guaranteed for 30 000 cycles AC-3 415V. GV7RS40 is a TeSys GV7R motor circuit breaker from Schneider Electric designed for motor applications 15-18.5kW@400V. It fulfills thermal-magnetic protection with a thermal setting range 25-40A, magnetic tripping at 12-14xIn and breaking capacity Icu 70kA@400V. Start-stop control by rocker lever guaranteed for 30 000 cycles AC-3 415V. Available worldwide, it is multi-standards certified (IEC, UL, CSA, Marine). Complete motor protection in a single device , short-circuit, overload, disconnection. Associated with a TeSys contactor, it ensures a complete type 1 or type 2 Motor Starter solution. For large industrial or building LV distribution networks thanks to a high 70kA breaking capacity. Power connections with screw clamp terminals. Manual control with rocker lever for Start / Stop, padlockable with accessory (GV7V). Possible integration of auxiliary contacts (GV7AB, GV7AD, GV7AE) for status and tripping signaling. Possible integration of undervoltage or shunt tripping units (GV7AU, GV7AS).
TeSys GV7 Manual Starter and Protector, thermal magnetic circuit protector, rocker lever, 3 P, AC-3, 60…100 A, high interrupt
TeSys GV7 Manual Starter and Protector, thermal magnetic circuit protector, rocker lever, 3 P, AC-3, 60…100 A, high interrupt
SKU: 482781
Category: Starters & Contactors
Reviews (0)
Be the first to review “TeSys GV7 Manual Starter and Protector, thermal magnetic circuit protector, rocker lever, 3 P, AC-3, 60…100 A, high interrupt” Cancel reply
Related products
Contactor, Type S, multipole lighting, mechanically held, 200A, 2 pole, 440/480 VAC 50/60 Hz coil, NEMA 12
Contactor, Type S, multipole lighting, mechanically held, 200A, 2 pole, 440/480 VAC 50/60 Hz coil, NEMA 12
Contactor, Type S, multipole lighting, electrically held, 400A, 3 pole, 550/600 V 50/60 Hz coil, open style
Contactor, Type S, multipole lighting, electrically held, 400A, 3 pole, 550/600 V 50/60 Hz coil, open style
Contactor, Definite Purpose, 40A, 2 pole, 7.5HP at 230VAC, 1 phase, 208/240VAC 60Hz 220VAC 50Hz coil, open
Contactor, Definite Purpose, 40A, 2 pole, 7.5HP at 230VAC, 1 phase, 208/240VAC 60Hz 220VAC 50Hz coil, open
NEMA Contactor, Type S, reversing, horizontal, Size 00, 9A, 1 HP at 230 VAC, single phase, up to 100 kA, 2 pole, 208 VAC coil, open style
NEMA Contactor, Type S, reversing, horizontal, Size 00, 9A, 1 HP at 230 VAC, single phase, up to 100 kA, 2 pole, 208 VAC coil, open style
IEC contactor, TeSys Deca, nonreversing, 38A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
IEC contactor, TeSys Deca, nonreversing, 38A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
Ambient Compensated Bimetallic Thermal Unit Class 20
Ambient Compensated Bimetallic Thermal Unit Class 20
Contactor, Type L, multipole lighting, mechanically held, 30A, 3 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 3R/12
Contactor, Type L, multipole lighting, mechanically held, 30A, 3 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 3R/12
Switch, manual, 30A, 3 pole, 10 HP at 575 VAC, three phase, toggle operated, no indicator, open style
Switch, manual, 30A, 3 pole, 10 HP at 575 VAC, three phase, toggle operated, no indicator, open style
Reviews