Type S NEMA motor starters are used for full voltage starting and stopping of AC squirrel cage motors. Type S motor starters have ratings up to 810 amperes. This 3 pole NEMA Size 5 non-reversing starter has a 270 ampere rating. This NEMA Size 5 motor starter has 3 phase ratings of 75 HP at 200 VAC, 100 HP at 230 VAC and 200 HP at 460 and 575 VAC. This non-reversing NEMA motor starter has a Motor Logic overload relay with a 90A to 270A range to sense over current conditions. This NEMA starter has a 100 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 110/120 VAC 50/60 Hz operating coil wired for separate control. This NEMA starter is an open device without an enclosure. This starter is 17.56 inches tall, 8.56 inches wide and 8.75 inches deep. A wide variety of accessories are available for Type S starters. Type S non-reversing NEMA motor starters are UL listed and CSA certified.
NEMA motor starter, Type S, nonreversing, Size 5, 270A, 200HP at 460VAC, up to 100kA SCCR, 3 phase, 3 pole, Motor Logic, 120VAC coil, open
NEMA motor starter, Type S, nonreversing, Size 5, 270A, 200HP at 460VAC, up to 100kA SCCR, 3 phase, 3 pole, Motor Logic, 120VAC coil, open
SKU: 1336237
Category: NEMA Contactors & Starters
Reviews (0)
Be the first to review “NEMA motor starter, Type S, nonreversing, Size 5, 270A, 200HP at 460VAC, up to 100kA SCCR, 3 phase, 3 pole, Motor Logic, 120VAC coil, open” Cancel reply
Related products
NEMA Contactor, TeSys N, reversing, Size 2, 45A, 25HP at 460VAC, 3 pole, 3 phase, 120VAC 50/60Hz coil, open
NEMA Contactor, TeSys N, reversing, Size 2, 45A, 25HP at 460VAC, 3 pole, 3 phase, 120VAC 50/60Hz coil, open
IEC contactor, TeSys Deca, nonreversing, 80A resistive, 4 pole, 4 NO, 110VAC 50/60Hz coil, open style
IEC contactor, TeSys Deca, nonreversing, 80A resistive, 4 pole, 4 NO, 110VAC 50/60Hz coil, open style
TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 115 A – coil 380 V AC
TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 380 V AC
Contactor, IEC, TeSys K, 9A, 3 P, 5 HP at 480VAC, nonreversing, 1 NO auxilliary contact, 120VAC 50/60 Hz coil
Contactor, IEC, TeSys K, 9A, 3 P, 5 HP at 480VAC, nonreversing, 1 NO auxilliary contact, 120VAC 50/60 Hz coil
NEMA Starter, Type S, reversing, vertical, Size 5, 270A, 200 HP at 575 VAC, 10 kA SCCR, 3 phase, 3 pole, melting alloy overload, 120 VAC coil, open
NEMA Starter, Type S, reversing, vertical, Size 5, 270A, 200 HP at 575 VAC, 10 kA SCCR, 3 phase, 3 pole, melting alloy overload, 120 VAC coil, open
Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NO, 48VAC coil
Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NO, 48VAC coil
TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 225 A – coil 240 V AC
TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 225 A - coil 240 V AC
Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NO, 220 to 230VAC coil
Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NO, 220 to 230VAC coil
Reviews
There are no reviews yet.