Type S NEMA motor starters are used for full voltage starting and stopping of AC squirrel cage motors. Type S motor starters have ratings up to 810 amperes. This 3 pole NEMA Size 0 non-reversing starter has an 18 ampere rating. NEMA Size 0 motor starters have 3 phase ratings of 3 HP at 200 and 230 VAC and 5 HP at 460 and 575 VAC. This non-reversing NEMA motor starter has a Motor Logic overload relay with a 6A to 18A range to sense over current conditions. This NEMA starter has a 100 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 208 VAC 60 Hz operating coil wired for common control. This NEMA starter is an open device without an enclosure. This starter is 6.77 inches tall, 3.50 inches wide and 4.22 inches deep. A wide variety of accessories are available for Type S starters. Type S non-reversing NEMA motor starters are UL listed and CSA certified.
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic, 208 VAC coil, open
NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic, 208 VAC coil, open
SKU: 14621024
Category: NEMA Contactors & Starters
Reviews (0)
Be the first to review “NEMA Motor Starter, Type S, nonreversing, Size 0, 18A, 5 HP at 460 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic, 208 VAC coil, open” Cancel reply
Related products
Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NO, 220 to 230VAC coil
Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NO, 220 to 230VAC coil
NEMA Contactor, TeSys N, reversing, Size 2, 45A, 25HP at 460VAC, 3 pole, 3 phase, 120VAC 50/60Hz coil, open
NEMA Contactor, TeSys N, reversing, Size 2, 45A, 25HP at 460VAC, 3 pole, 3 phase, 120VAC 50/60Hz coil, open
TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 115 A – coil 120 V AC
TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 115 A - coil 120 V AC
NEMA combination starter, Type S, 60A fusible disconnect, Size 2, 45A, 25HP at 600VAC, 3 phase, 3 pole, Motor Logic SSOLR, 120VAC coil, NEMA 1
NEMA combination starter, Type S, 60A fusible disconnect, Size 2, 45A, 25HP at 600VAC, 3 phase, 3 pole, Motor Logic SSOLR, 120VAC coil, NEMA 1
IEC contactor, TeSys Deca, nonreversing, 60A resistive, 4 pole, 2 NO and 2 NC, 230VAC 50/60Hz coil, open style
IEC contactor, TeSys Deca, nonreversing, 60A resistive, 4 pole, 2 NO and 2 NC, 230VAC 50/60Hz coil, open style
NEMA Contactor and NEMA Motor Starter, Type S, replacement contact kit, 8502SG, 8536SG, 8903SX, NEMA size 5, 300A, 3 pole
NEMA Contactor and NEMA Motor Starter, Type S, replacement contact kit, 8502SG, 8536SG, 8903SX, NEMA size 5, 300A, 3 pole
NEMA Starter, Type S, reversing, vertical, Size 5, 270A, 200 HP at 575 VAC, 10 kA SCCR, 3 phase, 3 pole, melting alloy overload, 120 VAC coil, open
NEMA Starter, Type S, reversing, vertical, Size 5, 270A, 200 HP at 575 VAC, 10 kA SCCR, 3 phase, 3 pole, melting alloy overload, 120 VAC coil, open
IEC contactor, TeSys Deca, nonreversing, 80A resistive, 4 pole, 4 NO, 110VAC 50/60Hz coil, open style
IEC contactor, TeSys Deca, nonreversing, 80A resistive, 4 pole, 4 NO, 110VAC 50/60Hz coil, open style
Reviews
There are no reviews yet.