8911 definite purpose starters are inexpensive starters for applications with relatively low duty cycles. Typical applications include air compressors, agricultural equipment, pumps, and HVAC equipment. This three pole definite purpose starter has a full load rating of 20 amperes. This starter has ratings of 1.5 HP at 115 VAC and 3 HP at 230 VAC single phase. It has a 7.5 HP at 230 VAC, 460 VAC and 575 VAC three phase. The nonreplaceable coil is available with a variety of coil voltages. This device has a 440/480 VAC 50/60 Hz coil. The starter has straight through wiring. The melting alloy type overload relay uses Type B thermal units to sense over current conditions. A painted sheet steel NEMA 1 general purpose enclosure is used to protect this definite purpose starter. Enclosure is 8.50 inches tall, 4.84 inches wide and 4.02 inches deep. Auxiliary contacts are available for these starters. 8911DPS definite purpose starters are UL component recognized.
Starter, Definite Purpose, nonreversing, 20A, 3 pole, 3 phase, 440/480VAC 50/60Hz coil, melting alloy overload, NEMA 1
Starter, Definite Purpose, nonreversing, 20A, 3 pole, 3 phase, 440/480VAC 50/60Hz coil, melting alloy overload, NEMA 1
SKU: 15103102
Category: Starters & Contactors
Reviews (0)
Be the first to review “Starter, Definite Purpose, nonreversing, 20A, 3 pole, 3 phase, 440/480VAC 50/60Hz coil, melting alloy overload, NEMA 1” Cancel reply
Related products
Contactor, Type L, multipole lighting, mechanically held, 30A, 6 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 1, +option
Contactor, Type L, multipole lighting, mechanically held, 30A, 6 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 1, +option
Contactor, NIGHT MASTER, combination lighting, 30A, 3 pole, breaker, 24 VAC 60 Hz coil. NEMA 3R
Contactor, NIGHT MASTER, combination lighting, 30A, 3 pole, breaker, 24 VAC 60 Hz coil. NEMA 3R
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 110/120 VAC 50/60 Hz coil, open style
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 110/120 VAC 50/60 Hz coil, open style
TeSys GV7 Manual Starter and Protector, thermal magnetic circuit protector, rocker lever, 3 P, AC-3, 60…100 A, high interrupt
TeSys GV7 Manual Starter and Protector, thermal magnetic circuit protector, rocker lever, 3 P, AC-3, 60...100 A, high interrupt
Contactor, Type L, multipole lighting, mechanically held, 30A, 3 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 3R/12
Contactor, Type L, multipole lighting, mechanically held, 30A, 3 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 3R/12
NEMA starter, Type S, reversing, vertical, Size 3, 90A, 50HP at 575VAC, 5kA SSCR, 3 phase, 3 pole, melting alloy overload, 120VAC coil, open
NEMA starter, Type S, reversing, vertical, Size 3, 90A, 50HP at 575VAC, 5kA SSCR, 3 phase, 3 pole, melting alloy overload, 120VAC coil, open
Ambient Compensated Bimetallic Thermal Unit Class 20
Ambient Compensated Bimetallic Thermal Unit Class 20
Reviews
There are no reviews yet.