PowerPact B-frame circuit breaker, offers proven performance, flexibility, and reliability. This PowerPact Molded Case Circuit Breaker feature new innovations such as the patented EverLink™ connections. PowerPact B-frame circuit breakers provides economical thermal magnetic circuit protection with a breaking capacity of 25kA at 220/240 VAC, 50/60 Hz. PowerPact B-frame circuit breakers come in 1 to 4-pole unit mount construction also 1 to 3-pole I-Line construction. This PowerPact B, 100 A, 3P, circuit breaker has a breaking capacity of 18kA@480/277VAC@50/60 Hz per UL 489 standards. This circuit breaker has a thermal-magnetic trip unit technology with a mechanical service life of 20000 cycles and an electrical service life of 10000 cycles@440V. This I-Line breaker has a presence of auxiliary contacts green signaling function. The I-Line lug can accept an AWG gauge AWG 14 / AWG 2/0, aluminium/copper. This breakers complies to UL, IEC, CCC, EAC, CSA, NOM standards. Powerpact B-Frame breakers have an operating altitude test condition of 2000 m without derating and a 5000 m with derating. Dimensions for this product are 137 mm (H),81 mm (W),89 mm (D) and a weight of 1.315kg. This breaker has a continuous current rating of 80% with an CBA phase connection.
PowerPact B Circuit Breaker, 100A, 3P, 480Y/277V AC, 18kA at 480/277 UL, I-Line
PowerPact B Circuit Breaker, 100A, 3P, 480Y/277V AC, 18kA at 480/277 UL, I-Line
SKU: 4278395
Category: Power Distribution
Reviews (0)
Be the first to review “PowerPact B Circuit Breaker, 100A, 3P, 480Y/277V AC, 18kA at 480/277 UL, I-Line” Cancel reply
Related products
Circuit breaker, PowerPact H, thermal magnetic, 80A, 3 pole, 600V, 25kA, shunt trip, control wire both ends
Circuit breaker, PowerPact H, thermal magnetic, 80A, 3 pole, 600V, 25kA, shunt trip, control wire both ends
Circuit breaker accessory, PowerPacT J, rear connection kit, 3 pole, mixed, 4x short, 2x covers
Circuit breaker accessory, PowerPacT J, rear connection kit, 3 pole, mixed, 4x short, 2x covers
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Tap box, I-Line Busway, plug-in, 100A, 3 phase, 4 wire, 600VAC
Mini CB, QO, 20 A, 2P, 120 V, 10 kA, Plug in, SWN, 50Deg
Mini CB, QO, 20 A, 2P, 120 V, 10 kA, Plug in, SWN, 50Deg
Multi 9 – C60H – MCB – 4P – 63 A – D Curve – 415 V – 15 kA
Multi 9 - C60H - MCB - 4P - 63 A - D Curve - 415 V - 15 kA
Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0A, 80%
Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0A, 80%
Multi 9 – C60 UL489 – MCB – 3P – 13 A – D Curve – 240 V – 10 kA – ring term
Multi 9 - C60 UL489 - MCB - 3P - 13 A - D Curve - 240 V - 10 kA - ring term
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise
Transformer, Type TF, industrial control, 100 VA, 120/240 VAC primary / 24 VAC secondary, 1 phase, 50/60 Hz, 55 °C rise