E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 50A, 1 pole, and has an operating voltage of 600Y/347 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 630A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
Mini circuit breaker, E-Frame, 50A, 1 pole, 600Y/347 VAC, 25 kA max, bolt on
Mini circuit breaker, E-Frame, 50A, 1 pole, 600Y/347 VAC, 25 kA max, bolt on
SKU: 172564942
Category: Load Centers & Panel Boards
Reviews (0)
Be the first to review “Mini circuit breaker, E-Frame, 50A, 1 pole, 600Y/347 VAC, 25 kA max, bolt on” Cancel reply
Related products
Panelboard interior, NQ, main breaker, 225A, Cu bus, 42 pole spaces, 3 phase, 4 wire, 240VAC, 48VDC, column width
Panelboard interior, NQ, main breaker, 225A, Cu bus, 42 pole spaces, 3 phase, 4 wire, 240VAC, 48VDC, column width
Panelboard enclosure cover, NQ, NEMA 1, flush, 15.52in W x 39.52in H
Panelboard enclosure cover, NQ, NEMA 1, flush, 15.52in W x 39.52in H
Mini circuit breaker, E-Frame, 20A, 2 pole, 480Y/277 VAC, 100 kA max, bolt on, shunt trip
Mini circuit breaker, E-Frame, 20A, 2 pole, 480Y/277 VAC, 100 kA max, bolt on, shunt trip
Trim front, I-Line Panelboard, HCJ, flush mount, 4 pcs, 32in W x 91in H
Trim front, I-Line Panelboard, HCJ, flush mount, 4 pcs, 32in W x 91in H
Interior, I-Line Panelboard, HCP, 800A, w/main breaker, 72in CB space, for 42in W x 86in H x 9.5in D box, Cu bus
Interior, I-Line Panelboard, HCP, 800A, w/main breaker, 72in CB space, for 42in W x 86in H x 9.5in D box, Cu bus
Panelboard accessory, NF, lug kit, feed thru, 250A, aluminum
Panelboard accessory, NF, lug kit, feed thru, 250A, aluminum
Panelboard accessory, NQ, lug kit, compression, 100A, 8 to 1/0 AWG, Al
Panelboard accessory, NQ, lug kit, compression, 100A, 8 to 1/0 AWG, Al
NQ Panelboard Acc. Mechanical Lug Kit 225A, Aluminum/Copper
NQ Panelboard Acc. Mechanical Lug Kit 225A, Aluminum/Copper
Reviews
There are no reviews yet.