QO Load Centers offer premium features by allowing QO breakers, ground arc fault interrupters arc fault interrupters and surge arresters to be installed inside QO Load Centers enable the use of a full complement of accessories such as ground bars which are included here. Systems can be single or three phase and have indoor and outdoor versions. Indoor enclosures are designed to rotate 180 degrees to accommodate top or bottom service entrance feed which saves expensive service cable. QO Load Centers feature plated copper bus, providing superior performance and durability. This QO Load Center contains a main lug and is rated at 125 A and 1 phase. This system provides 24 spaces in a NEMA 3R enclosure and is hub ready. Load center is plug on neutral ready. Ground bar is included but is to be field installed. This 1 phase load center has 24 spaces and 34 circuits. This system provides 125A convertible main lugs in a NEMA 3R enclosure. It also includes plug on neutral, ground bar, and is UL rated.
Load center, QO, 1 phase, 24 spaces, 34 circuits, 125A convertible main lugs, PoN, NEMA3R, gnd bar, UL
Load center, QO, 1 phase, 24 spaces, 34 circuits, 125A convertible main lugs, PoN, NEMA3R, gnd bar, UL
SKU: 172550547
Category: Load Centers & Panel Boards
Reviews (0)
Be the first to review “Load center, QO, 1 phase, 24 spaces, 34 circuits, 125A convertible main lugs, PoN, NEMA3R, gnd bar, UL” Cancel reply
Related products
QO LoadCenter, Main Breaker, 200A, 1PH-3W, 30SP, NEMA 1, Ftry. Gnd.Bar
QO LoadCenter, Main Breaker, 200A, 1PH-3W, 30SP, NEMA 1, Ftry. Gnd.Bar
Panelboard enclosure cover, NQ, NEMA 1, flush, 15.52in W x 39.52in H
Panelboard enclosure cover, NQ, NEMA 1, flush, 15.52in W x 39.52in H
Interior, I-Line Panelboard, HCP, 800A, w/main breaker, 72in CB space, for 42in W x 86in H x 9.5in D box, Cu bus
Interior, I-Line Panelboard, HCP, 800A, w/main breaker, 72in CB space, for 42in W x 86in H x 9.5in D box, Cu bus
NF Panelboard Acc. Branch Deadfront Kit 125A, 3 Phase, 54 CCT, Thru Feed Lug
NF Panelboard Acc. Branch Deadfront Kit 125A, 3 Phase, 54 CCT, Thru Feed Lug
Load center, QO, 1 phase, 30 spaces, 30 circuits, 200A convertible main breaker, PoN, NEMA1, Qwik-grip, UL
Load center, QO, 1 phase, 30 spaces, 30 circuits, 200A convertible main breaker, PoN, NEMA1, Qwik-grip, UL
Load center accessory, Homeline, spare parts, groundng kit, 400A to 600A, 2 or 3 pole, set of 2
Load center accessory, Homeline, spare parts, groundng kit, 400A to 600A, 2 or 3 pole, set of 2
Panelboard enclosure box, NQ, Type 1, 14in W x 44in H x 5.75in D
Panelboard enclosure box, NQ, Type 1, 14in W x 44in H x 5.75in D
Reviews
There are no reviews yet.