Linergy TR is terminal block for Linergy. It belongs to fuse disc terminal with 4 mm² nominal cross section. The rated operational voltage is 600V conforming to CSA/cURus and 500V conforming to EN/IEC 60947-7-1. The rated current is 6.3A conforming to EN/IEC 60947-7-1, 6.3A conforming to CSA and 12A cURus. It has black surface treatment. Mounting by clip-on and sideways connection with 5x20mm fuse. It could be connection and disconnection by screwdriver. It is compatible with spacial enclosures for Prisma G, Prisma P, Pragma, Prisma PH, Prisma Pack, Spacial, Kaedra, TeSys. Sold in lots of 50 units. Ambient air temperature for operation is from -40 to 130 °C conforming to IEC 60216-1 and VDE 0304-T21. Multi standards certified (CSA, cURus, EAC). It is compliant with Green Premium (RoHS/REACH).
Terminal block, Linergy TR, fused disconnect type, for 5×20/25/30mm fuse, with led 12 to 30V, 2 points, black
Terminal block, Linergy TR, fused disconnect type, for 5×20/25/30mm fuse, with led 12 to 30V, 2 points, black
SKU: 172555327
Category: Automation & Control
Reviews (0)
Be the first to review “Terminal block, Linergy TR, fused disconnect type, for 5×20/25/30mm fuse, with led 12 to 30V, 2 points, black” Cancel reply
Related products
Set of 2 heavy duty vertical rails for fixing of chassis and cross rails-2000 mm
Set of 2 heavy duty vertical rails for fixing of chassis and cross rails-2000 mm
Contactor, Definite Purpose, 40A, 2 pole, 7.5 HP at 230 VAC, 1 phase, 440/480 VAC 50/60 Hz coil, open
Contactor, Definite Purpose, 40A, 2 pole, 7.5 HP at 230 VAC, 1 phase, 440/480 VAC 50/60 Hz coil, open
Limit switch, Limit switches XC Standard, XCMN, steel roller plunger, 1NC+1 NO, snap, cable
Limit switch, Limit switches XC Standard, XCMN, steel roller plunger, 1NC+1 NO, snap, cable
Disconnect Switch, TeSys LK4 Non fusible, 50hp at 600VAC, 3 pole, max 100A rated, plate mount
Disconnect Switch, TeSys LK4 Non fusible, 50hp at 600VAC, 3 pole, max 100A rated, plate mount
Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12…48 VDC, NC, cable 10 m
Inductive proximity sensors XS for hazardous area dust, M12, Sn4mm, 12...48 VDC, NC, cable 10 m
Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
Mechanical alternator, Square D Pumptrol, closed tank, NEMA 1, screw in bushing, 4NC DPST DB contacts
discrete output module Modicon Quantum – 32 O – positive logic (source)
discrete output module Modicon Quantum - 32 O - positive logic (source)

Reviews
There are no reviews yet.