QO load centers offer premium features by allowing QO breakers, ground arc fault interrupters arc fault interrupters and surge arresters to be installed inside QO load centers enable the use of a full complement of accessories. Systems can be single or three phase and have indoor and outdoor versions. Indoor enclosures are designed to rotate 180 degrees to accommodate top or bottom service entrance feed which saves expensive service cable. QO load centers feature plated copper bus, providing superior performance and durability. This single phase QO load center has fixed mains and is rated at 70 A at 120/240 VAC. This QO load center has a 10 kA breaking capacity. This system provides 2 spaces in a NEMA 1 enclosure. This load center has a surface cover. The lugs will accept 14 AWG to 4 AWG copper wire or 12 AWG to 3 AWG aluminum wire. The load center is 9.17 inches tall, 4.69 inches wide and 3.11 inches deep. The load center is CSA certified.
Load center, QO, 1 phase, 2 spaces, 2 circuits, 70A fixed main lugs, NEMA1, surface cover, UL
Load center, QO, 1 phase, 2 spaces, 2 circuits, 70A fixed main lugs, NEMA1, surface cover, UL
SKU: 172561281
Category: Load Centers & Panel Boards
Reviews (0)
Be the first to review “Load center, QO, 1 phase, 2 spaces, 2 circuits, 70A fixed main lugs, NEMA1, surface cover, UL” Cancel reply
Related products
Mini circuit breaker, E-Frame, 60A, 3 pole, 480Y/277 VAC, 100 kA max, bolt on, shunt trip
Mini circuit breaker, E-Frame, 60A, 3 pole, 480Y/277 VAC, 100 kA max, bolt on, shunt trip
NQ Panelboard Acc. Mechanical Lug Kit 225A, Aluminum/Copper
NQ Panelboard Acc. Mechanical Lug Kit 225A, Aluminum/Copper
OEM Mounting Base, ASE, 16 SP 125A, W/Lugs, No Neutral
OEM Mounting Base, ASE, 16 SP 125A, W/Lugs, No Neutral
Mini circuit breaker, E-Frame, 20A, 3 pole, 480Y/277 VAC, 25 kA max, bolt on, aux switch, alarm switch
Mini circuit breaker, E-Frame, 20A, 3 pole, 480Y/277 VAC, 25 kA max, bolt on, aux switch, alarm switch
Load center, QO, 1 phase, 30 spaces, 30 circuits, 200A convertible main breaker, PoN, NEMA1, Qwik-grip, UL
Load center, QO, 1 phase, 30 spaces, 30 circuits, 200A convertible main breaker, PoN, NEMA1, Qwik-grip, UL
QO LoadCenter, Main Breaker, 200A, 1PH-3W, 30SP, NEMA 1, Ftry. Gnd.Bar
QO LoadCenter, Main Breaker, 200A, 1PH-3W, 30SP, NEMA 1, Ftry. Gnd.Bar
Interior, I-Line Panelboard, HCP, 800A, w/main breaker, 72in CB space, for 42in W x 86in H x 9.5in D box, Cu bus
Interior, I-Line Panelboard, HCP, 800A, w/main breaker, 72in CB space, for 42in W x 86in H x 9.5in D box, Cu bus
Trim front, I-Line Panelboard, HCJ, flush mount, 4 pcs, 32in W x 91in H
Trim front, I-Line Panelboard, HCJ, flush mount, 4 pcs, 32in W x 91in H
Reviews
There are no reviews yet.