NQ Panelboard interiors can be used for applications such as commercial buildings, industrial buildings, stadiums, and offices. NQ Panelboards are versatile panelboards that feature a wide selection of circuit breakers, accessories, and ready to install kits. NQ Panelboard interiors are field convertible to top or bottom feed. NQ Panelboards are convertible from main lug to main breaker. NQ Panelboards provide 200% rated neutrals for nonlinear loads. Some factory installed options are split bus, lighting contactors, compression lugs, surge protection devices, and phenolic nameplates. This interior provides protection for your commercial and industrial applications. The main lugs are rated at 600A, 240 VAC 3 phase or 48 VDC. Interior has an interrupt current rating of up to 65 kA. This interior is for a 4 wire system with 54 spaces and has a copper bus bar. Interior is for QOB, QOBVH and QHB branch circuit breakers. Lug connections will accept two 1/0 AWG to 750 kcmil aluminum wire. This NQ panelboard interior is UL listed and CSA certified.
Panelboard interior, NQ, main lugs, 600A, Cu bus, 54 pole spaces, 3 phase, 4 wire, 240VAC, 48VDC
Panelboard interior, NQ, main lugs, 600A, Cu bus, 54 pole spaces, 3 phase, 4 wire, 240VAC, 48VDC
SKU: 172545450
Category: Load Centers & Panel Boards
Reviews (0)
Be the first to review “Panelboard interior, NQ, main lugs, 600A, Cu bus, 54 pole spaces, 3 phase, 4 wire, 240VAC, 48VDC” Cancel reply
Related products
Panelboard enclosure box, NQ, Type 1, 14in W x 44in H x 5.75in D
Panelboard enclosure box, NQ, Type 1, 14in W x 44in H x 5.75in D
Load center accessory, Homeline, spare parts, groundng kit, 400A to 600A, 2 or 3 pole, set of 2
Load center accessory, Homeline, spare parts, groundng kit, 400A to 600A, 2 or 3 pole, set of 2
Interior, I-Line PNLBRD, 400 A, main lugs, 31.50 in bar
Interior, I-Line PNLBRD, 400 A, main lugs, 31.50 in bar
Load center, QO, 1 phase, 30 spaces, 30 circuits, 200A convertible main breaker, PoN, NEMA1, Qwik-grip, UL
Load center, QO, 1 phase, 30 spaces, 30 circuits, 200A convertible main breaker, PoN, NEMA1, Qwik-grip, UL
Load center, QO, 3 phase, 42 spaces, 42 circuits, 125A convertible main breaker, NEMA3R, QDL, UL
Load center, QO, 3 phase, 42 spaces, 42 circuits, 125A convertible main breaker, NEMA3R, QDL, UL
Mini circuit breaker, E-Frame, 60A, 3 pole, 480Y/277 VAC, 100 kA max, bolt on, shunt trip
Mini circuit breaker, E-Frame, 60A, 3 pole, 480Y/277 VAC, 100 kA max, bolt on, shunt trip
Panelboard accessory, NF, lug kit, subfeed, 250A, aluminum
Panelboard accessory, NF, lug kit, subfeed, 250A, aluminum
Panelboard enclosure cover, NQ, NEMA 1, flush, 15.52in W x 39.52in H
Panelboard enclosure cover, NQ, NEMA 1, flush, 15.52in W x 39.52in H
Reviews
There are no reviews yet.