Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 3 pole NEMA Size 4 non-reversing contactor has a 135 ampere rating. Three phase NEMA Size 4 contactors have 40 HP at 200, 50 HP at 230 VAC and 100 HP at 460 and 575 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 110/120 VAC 50/60 Hz coil that is wired for separate control. This NEMA contactor is an open device without an enclosure. This contactor is 8.19 inches tall, 7.02 inches wide and 6.50 inches deep. A wide variety of accessories are available for Type S contactors. This contactor is supplied with three normally closed external interlocks. Type S NEMA contactors are UL listed and CSA certified.
NEMA Contactor, Type S, nonreversing, Size 4, 135A, 100 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 120 VAC coil, open
NEMA Contactor, Type S, nonreversing, Size 4, 135A, 100 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 120 VAC coil, open
SKU: 16946869
Category: Starters & Contactors
Reviews (0)
Be the first to review “NEMA Contactor, Type S, nonreversing, Size 4, 135A, 100 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 120 VAC coil, open” Cancel reply
Related products
Panelboard lighting contactor auxiliary contact module, top assembly, 1NO-1NC
Panelboard lighting contactor auxiliary contact module, top assembly, 1NO-1NC
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 80 A – 12 V AC 50 Hz coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 80 A - 12 V AC 50 Hz coil
Contactor, Type L, multipole lighting, mechanically held, 30A, 6 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 1, +option
Contactor, Type L, multipole lighting, mechanically held, 30A, 6 pole, 600 V, 110/120 VAC 50/60 Hz coil, NEMA 1, +option
NEMA starter, Type S, reversing, vertical, Size 3, 90A, 50HP at 575VAC, 5kA SSCR, 3 phase, 3 pole, melting alloy overload, 120VAC coil, open
NEMA starter, Type S, reversing, vertical, Size 3, 90A, 50HP at 575VAC, 5kA SSCR, 3 phase, 3 pole, melting alloy overload, 120VAC coil, open
Contactor, NIGHT MASTER, combination lighting, 30A, 3 pole, breaker, 24 VAC 60 Hz coil. NEMA 3R
Contactor, NIGHT MASTER, combination lighting, 30A, 3 pole, breaker, 24 VAC 60 Hz coil. NEMA 3R
NEMA Contactor and NEMA Motor Starter, Type S, nonreversing, enclosure, NEMA Size 00, 0, 1, 8903SM lighting, NEMA 3R
NEMA Contactor and NEMA Motor Starter, Type S, nonreversing, enclosure, NEMA Size 00, 0, 1, 8903SM lighting, NEMA 3R
Reviews
There are no reviews yet.