TeSys N contactors and starters conform to NEMA ICS2 standards. The NEMA size is printed directly on the face of the contactor. This NEMA size 00 reversing contactor consists of contactors that are mechanically and electrically interlocked. This 3 pole reversing contactor mounts on 35mm DIN rail and has a 9 amperage continuous current rating. This contactor has 0.33 HP at 115 VAC and 1 HP at 230 VAC single phase ratings. The contactor also has ratings of 1.5 HP at 200 to 230 VAC and 2 HP at 460 and 575 VAC poly phase. The reversing contactor is wired for common control with a 120 VAC 50/60 Hz replaceable coil. Contactor has 1 normally open and 1 normally closed auxiliary contact. This contactor is not in an enclosure. This contactor is 3.71 inches tall, 3.53 inches wide and 3.66 inches deep. It weighs 2.08 lbs. The screw clamp terminals will accept power wires from 18 AWG to 8 AWG and control wires from 18 AWG to 10 AWG. This TeSys N contactor is UL listed and CSA Certified.
NEMA Contactor, TeSys N, reversing, Size 00, 9A, 2HP at 460VAC, 3 pole, 3 phase, 120VAC 50/60Hz coil, open
NEMA Contactor, TeSys N, reversing, Size 00, 9A, 2HP at 460VAC, 3 pole, 3 phase, 120VAC 50/60Hz coil, open
SKU: 489330
Category: Starters & Contactors
Reviews (0)
Be the first to review “NEMA Contactor, TeSys N, reversing, Size 00, 9A, 2HP at 460VAC, 3 pole, 3 phase, 120VAC 50/60Hz coil, open” Cancel reply
Related products
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 110/120 VAC 50/60 Hz coil, open style
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 110/120 VAC 50/60 Hz coil, open style
Contactor, Type S, multipole lighting, electrically held, 400A, 3 pole, 550/600 V 50/60 Hz coil, open style
Contactor, Type S, multipole lighting, electrically held, 400A, 3 pole, 550/600 V 50/60 Hz coil, open style
TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 80 A – 12 V AC 50 Hz coil
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 80 A - 12 V AC 50 Hz coil
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 277 VAC 60 Hz coil, NEMA 1, +option
Contactor, Type L, multipole lighting, mechanically held, 30A, 10 pole, 600 V, 277 VAC 60 Hz coil, NEMA 1, +option
Reversing ultra compact starter, TeSys Hybrid, 3P, 500VAC, 0.75kW at 400V, 110 to 230VAC, Spring terminal
Reversing ultra compact starter, TeSys Hybrid, 3P, 500VAC, 0.75kW at 400V, 110 to 230VAC, Spring terminal
Panelboard lighting contactor auxiliary contact module, top assembly, 1NO-1NC
Panelboard lighting contactor auxiliary contact module, top assembly, 1NO-1NC
Reviews
There are no reviews yet.